Datasheet
Central Processor Unit (CPU)
MC68HC908GZ60 • MC68HC908GZ48 • MC68HC908GZ32 Data Sheet, Rev. 6
102 Freescale Semiconductor
7.3.5 Condition Code Register
The 8-bit condition code register contains the interrupt mask and five flags that indicate the results of the 
instruction just executed. Bits 6 and 5 are set permanently to 1. The following paragraphs describe the 
functions of the condition code register.
V — Overflow Flag
The CPU sets the overflow flag when a two's complement overflow occurs. The signed branch 
instructions BGT, BGE, BLE, and BLT use the overflow flag.
1 = Overflow
0 = No overflow
H — Half-Carry Flag
The CPU sets the half-carry flag when a carry occurs between accumulator bits 3 and 4 during an 
add-without-carry (ADD) or add-with-carry (ADC) operation. The half-carry flag is required for 
binary-coded decimal (BCD) arithmetic operations. The DAA instruction uses the states of the H and 
C flags to determine the appropriate correction factor.
1 = Carry between bits 3 and 4
0 = No carry between bits 3 and 4
I — Interrupt Mask
When the interrupt mask is set, all maskable CPU interrupts are disabled. CPU interrupts are enabled 
when the interrupt mask is cleared. When a CPU interrupt occurs, the interrupt mask is set 
automatically after the CPU registers are saved on the stack, but before the interrupt vector is fetched.
1 = Interrupts disabled
0 = Interrupts enabled
NOTE
To maintain M6805 Family compatibility, the upper byte of the index 
register (H) is not stacked automatically. If the interrupt service routine 
modifies H, then the user must stack and unstack H using the PSHH and 
PULH instructions.
After the I bit is cleared, the highest-priority interrupt request is serviced first.
A return-from-interrupt (RTI) instruction pulls the CPU registers from the stack and restores the 
interrupt mask from the stack. After any reset, the interrupt mask is set and can be cleared only by the 
clear interrupt mask software instruction (CLI).
N — Negative Flag
The CPU sets the negative flag when an arithmetic operation, logic operation, or data manipulation 
produces a negative result, setting bit 7 of the result.
1 = Negative result
0 = Non-negative result
Bit 7654321Bit 0
Read:
V11HINZC
Write:
Reset:X11X1XXX
X = Indeterminate
Figure 7-6. Condition Code Register (CCR)