Datasheet

MSCAN Controller
Technical Data MC68HC912D60A — Rev. 3.1
308 MSCAN Controller Freescale Semiconductor
Figure 17-2. User Model for Message Buffer Organization
When the msCAN12 module is transmitting, the msCAN12 receives its
own messages into the background receive buffer, RxBG, but does NOT
overwrite RxFG, generate a receive interrupt or acknowledge its own
messages on the CAN bus. The exception to this rule is in loop-back
mode (see msCAN12 Module Control Register 1 (CMCR1).) where the
msCAN12 treats its own messages exactly like all other incoming
messages. The msCAN12 receives its own transmitted messages in the
event that it loses arbitration. If arbitration is lost, the msCAN12 must be
prepared to become receiver.
RxFG
RxBG
Tx0
RXF
TXE
PRIO
Tx1
TXE
PRIO
Tx2
TXE
PRIO
msCAN12 CPU bus