Datasheet

Analog-to-Digital Converter
Technical Data MC68HC912D60A — Rev. 3.1
362 Analog-to-Digital Converter Freescale Semiconductor
ASCIE — ATD Sequence Complete Interrupt Enable
0 = Disables ATD interrupt
1 = Enables ATD interrupt on Sequence Complete
The sequence complete interrupt function signals the MCU when a
conversion sequence is complete. At this time, the result registers
contain the result data generated by the conversion sequence. If this
interrupt function is disabled, then the conversion complete flags must
be polled to determine when a conversion or a conversion sequence
is complete. Note that reset clears pending interrupts.
ASCIFATD Sequence Complete Interrupt Flag
0 = No ATD sequence complete interrupt occurred
1 = ATD sequence complete interrupt occurred
The sequence complete interrupt flag. This flag is not cleared until the
interrupt is serviced (by reading the result data in such a way that the
conversion complete flag is cleared), a new conversion sequence is
initiated, or the module is reset. This bit is not writable in any mode.
Input Signal
Vrl = 0 Volts
Vrh = 5.12 Volts
8-Bit
Codes
10-Bit
Codes
5.120 Volts
5.100
5.080
2.580
2.560
2.540
0.020
0.000
FF
FF
FE
81
80
7F
01
00
FFC0
FF00
FE00
8100
8000
7F00
0100
0000
Table 18-2. Left Justified ATD Output Codes