Datasheet

Appendix A Electrical Characteristics and Timing Specifications
MC9S08AC16 Series Data Sheet, Rev. 9
Freescale Semiconductor 301
A.7 Supply Current Characteristics
Table A-7. Supply Current Characteristics
Num C Parameter Symbol
V
DD
(V)
Typ
1
1
Typical values are based on characterization data at 25C unless otherwise stated. See Figure A-5 through Figure A-7 for
typical curves across voltage/temperature.
Max
2
2
Values given here are preliminary estimates prior to completing characterization.
Unit
Temp
(C)
1C
Run supply current
3
measured at
(CPU clock = 2 MHz, f
Bus
= 1 MHz)
3
All modules except ADC active, ICG configured for FBE, and does not include any dc loads on port pins
RI
DD
51.01.2
4
4
Every unit tested to this parameter. All other values in the Max column are guaranteed by characterization.
mA –40 to 125C
30.851.1
2C
Run supply current
5
measured at
(CPU clock = 16 MHz, f
Bus
= 8 MHz)
5
All modules except ADC active, ICG configured for FBE, and does not include any dc loads on port pins
RI
DD
56.58.0
6
6
Every unit tested to this parameter. All other values in the Max column are guaranteed by characterization.
mA –40 to 125C
35.56.0
3P
Run supply current
7
measured at (CPU
clock = 40 MHz, f
Bus
= 20 MHz)
7
All modules except ADC active, ICG configured for FBE and does not include any DC loads on port pins
RI
DD
5 16.5 20 mA –40 to 125C
3 11.5 15 mA –40 to 125C
4C
Stop2 mode supply current
S2I
DD
51.36
11
20
60
4
A
0 to 70C
–40 to 85C
–40 to 125C
31.05
10.5
17
50
A
0 to 70C
–40 to 85C
–40 to 125C
5C
Stop3 mode supply current
S3I
DD
51.49
12
20
90
4
A
0 to 70C
–40 to 85C
–40 to 125C
31.15
11
19
85
A
0 to 70C
–40 to 85C
–40 to 125C
6C
RTI adder to stop2 or stop3
8
8
Most customers are expected to find that auto-wakeup from stop2 or stop3 can be used instead of the higher current wait
mode. Wait mode typical is 560 A at 3 V with f
Bus
= 1 MHz.
S23I
DDRTI
5300
500
500
nA
–40 to 85C
–40 to 125C
3300
500
500
nA
–40 to 85C
–40 to 125C
7 C LVD adder to stop3 (LVDE = LVDSE = 1)
S3I
DDLVD
5116
150
180
A
–40 to 85C
–40 to 125C
390
140
160
A
–40 to 85C
–40 to 125C
8C
Adder to stop3 for oscillator enabled
9
(OSCSTEN =1)
9
Values given under the following conditions: low range operation (RANGE = 0) with a 32.768kHz crystal, low power mode
(HGO = 0), clock monitor disabled (LOCD = 1).
S3I
DDOSC
5,3 5
6
8
A
A
–40 to 85C