Datasheet

Chapter 8 Internal Clock Generator (S08ICGV4)
MC9S08AW60 Data Sheet, Rev 2
132 Freescale Semiconductor
Digitally-controlled oscillator (DCO) preserves previous frequency settings, allowing fast
frequency lock when recovering from stop3 mode
DCO will maintain operating frequency during a loss or removal of reference clock
Post-FLL divider selects 1 of 8 bus rate divisors (/1 through /128)
Separate self-clocked source for real-time interrupt
Trimmable internal clock source supports SCI communications without additional external
components
Automatic FLL engagement after lock is acquired
External oscillator selectable for low power or high gain
8.1.2 Modes of Operation
This is a high-level description only. Detailed descriptions of operating modes are contained in
Section 8.4, “Functional Description.”
Mode 1 — Off
The output clock, ICGOUT, is static. This mode may be entered when the STOP instruction is
executed.
Mode 2 — Self-clocked (SCM)
Default mode of operation that is entered immediately after reset. The ICG’s FLL is open loop and
the digitally controlled oscillator (DCO) is free running at a frequency set by the filter bits.
Mode 3 — FLL engaged internal (FEI)
In this mode, the ICG’s FLL is used to create frequencies that are programmable multiples of the
internal reference clock.
FLL engaged internal unlocked is a transition state that occurs while the FLL is attempting to
lock. The FLL DCO frequency is off target and the FLL is adjusting the DCO to match the
target frequency.
FLL engaged internal locked is a state that occurs when the FLL detects that the DCO is locked
to a multiple of the internal reference.
Mode 4 — FLL bypassed external (FBE)
In this mode, the ICG is configured to bypass the FLL and use an external clock as the clock source.
Mode 5 — FLL engaged external (FEE)
The ICG’s FLL is used to generate frequencies that are programmable multiples of the external
clock reference.
FLL engaged external unlocked is a transition state that occurs while the FLL is attempting to
lock. The FLL DCO frequency is off target and the FLL is adjusting the DCO to match the
target frequency.
FLL engaged external locked is a state which occurs when the FLL detects that the DCO is
locked to a multiple of the internal reference.