Datasheet
Table 4-2. Peripheral registers availability
Address Bytes Peripheral registers
0x0000—0x0007 8 Port data
0x0010—0x0017 8 ADC
0x0018—0x001B 4 MTIM0
0x001C—0x001F 4 MTIM1
0x0020—0x002A 11 FTM0
0x002C—0x002F 4 ACMP
0x0030—0x003A 11 FTM1
0x003B—0x003B 1 IRQ
0x003C—0x003C 1 KBI0
0x003D—0x003D 1 KBI1
0x003E—0x003F 2 IPC
0x3000—0x300B 12 SIM
0x300C—0x300F 4 SCG
0x3010—0x301F 16 DBG
0x3020—0x302C 13 NVM
0x3030—0x3037 8 WDOG
0x3038—0x303E 7 ICS, XOSC
0x3040—0x3049 10 PMC
0x304A—0x304B 2 SYS
0x3050—0x3059 10 IPC
0x3060—0x3068 9 CRC
0x306A—0x306F 6 RTC
0x3070—0x307B 12 IIC
0x307C—0x307D 2 KBI0
0x307E—0x307F 2 KBI1
0x3080—0x3087 8 SCI0
0x3088—0x308F 8 SCI1
0x3090—0x3097 8 SCI2
0x3098—0x309F 8 SPI0
0x30A0—0x30A9 10 SPI1
0x30AC—0x30AD 2 ADC
0x30AF—0x30AF 1 Port high drive enable
0x30B0—0x30B7 8 Port output enable
0x30B8—0x30BF 8 Port input enable
0x30C0—0x30EA 43 FTM2
0x30EC—0x30EF 4 Port filter
0x30F0—0x30F7 8 Port pullup
0x30F8—0x30FF 8 SYS
The registers in the devices are divided into two groups:
Register addresses and bit assignments
MC9S08PA60 Reference Manual, Rev. 1, 9/2012
62 Freescale Semiconductor, Inc.