Datasheet
Development Support
MC9S08QG8 and MC9S08QG4 Data Sheet, Rev. 5
Freescale Semiconductor   255
A Then B — Trigger when the address matches the value in comparator B but only after the address for 
another cycle matched the value in comparator A. There can be any number of cycles after the A match 
and before the B match.
A AND B Data (Full Mode) — This is called a full mode because address, data, and R/W (optionally) 
must match within the same bus cycle to cause a trigger event. Comparator A checks address, the low byte 
of comparator B checks data, and R/W is checked against RWA if RWAEN = 1. The high-order half of 
comparator B is not used.
In full trigger modes it is not useful to specify a tag-type CPU breakpoint (BRKEN = TAG = 1), but if you 
do, the comparator B data match is ignored for the purpose of issuing the tag request to the CPU and the 
CPU breakpoint is issued when the comparator A address matches.
A AND NOT B Data (Full Mode) — Address must match comparator A, data must not match the low 
half of comparator B, and R/W must match RWA if RWAEN = 1. All three conditions must be met within 
the same bus cycle to cause a trigger.
In full trigger modes it is not useful to specify a tag-type CPU breakpoint (BRKEN = TAG = 1), but if you 
do, the comparator B data match is ignored for the purpose of issuing the tag request to the CPU and the 
CPU breakpoint is issued when the comparator A address matches.
Event-Only B (Store Data) — Trigger events occur each time the address matches the value in 
comparator B. Trigger events cause the data to be captured into the FIFO. The debug run ends when the 
FIFO becomes full.
A Then Event-Only B (Store Data) — After the address has matched the value in comparator A, a trigger 
event occurs each time the address matches the value in comparator B. Trigger events cause the data to be 
captured into the FIFO. The debug run ends when the FIFO becomes full.
Inside Range (A ≤ Address ≤ B) — A trigger occurs when the address is greater than or equal to the value 
in comparator A and less than or equal to the value in comparator B at the same time.
Outside Range (Address < A or Address > B) — A trigger occurs when the address is either less than 