Datasheet
Table Of Contents
- MC9S08SH8DS_Readme
- MC9S08SH8_DSAD_Rev.1
- MC9S08SH8
- Chapter 1 Device Overview
- Chapter 2 Pins and Connections
- Chapter 3 Modes of Operation
- Chapter 4 Memory
- Chapter 5 Resets, Interrupts, and General System Control
- 5.1 Introduction
- 5.2 Features
- 5.3 MCU Reset
- 5.4 Computer Operating Properly (COP) Watchdog
- 5.5 Interrupts
- 5.6 Low-Voltage Detect (LVD) System
- 5.7 Reset, Interrupt, and System Control Registers and Control Bits
- 5.7.1 Interrupt Pin Request Status and Control Register (IRQSC)
- 5.7.2 System Reset Status Register (SRS)
- 5.7.3 System Background Debug Force Reset Register (SBDFR)
- 5.7.4 System Options Register 1 (SOPT1)
- 5.7.5 System Options Register 2 (SOPT2)
- 5.7.6 System Device Identification Register (SDIDH, SDIDL)
- 5.7.7 System Power Management Status and Control 1 Register (SPMSC1)
- 5.7.8 System Power Management Status and Control 2 Register (SPMSC2)
- Chapter 6 Parallel Input/Output Control
- 6.1 Port Data and Data Direction
- 6.2 Pull-up, Slew Rate, and Drive Strength
- 6.3 Ganged Output
- 6.4 Pin Interrupts
- 6.5 Pin Behavior in Stop Modes
- 6.6 Parallel I/O and Pin Control Registers
- 6.6.1 Port A Registers
- 6.6.1.1 Port A Data Register (PTAD)
- 6.6.1.2 Port A Data Direction Register (PTADD)
- 6.6.1.3 Port A Pull Enable Register (PTAPE)
- 6.6.1.4 Port A Slew Rate Enable Register (PTASE)
- 6.6.1.5 Port A Drive Strength Selection Register (PTADS)
- 6.6.1.6 Port A Interrupt Status and Control Register (PTASC)
- 6.6.1.7 Port A Interrupt Pin Select Register (PTAPS)
- 6.6.1.8 Port A Interrupt Edge Select Register (PTAES)
- 6.6.2 Port B Registers
- 6.6.2.1 Port B Data Register (PTBD)
- 6.6.2.2 Port B Data Direction Register (PTBDD)
- 6.6.2.3 Port B Pull Enable Register (PTBPE)
- 6.6.2.4 Port B Slew Rate Enable Register (PTBSE)
- 6.6.2.5 Port B Drive Strength Selection Register (PTBDS)
- 6.6.2.6 Port B Interrupt Status and Control Register (PTBSC)
- 6.6.2.7 Port B Interrupt Pin Select Register (PTBPS)
- 6.6.2.8 Port B Interrupt Edge Select Register (PTBES)
- 6.6.3 Port C Registers
- 6.6.1 Port A Registers
- Chapter 7 Central Processor Unit (S08CPUV2)
- 7.1 Introduction
- 7.2 Programmer’s Model and CPU Registers
- 7.3 Addressing Modes
- 7.4 Special Operations
- 7.5 HCS08 Instruction Set Summary
- Chapter 8 Analog Comparator 5-V (S08ACMPV2)
- Chapter 9 Analog-to-Digital Converter (S08ADCV1)
- 9.1 Introduction
- 9.2 External Signal Description
- 9.3 Register Definition
- 9.3.1 Status and Control Register 1 (ADCSC1)
- 9.3.2 Status and Control Register 2 (ADCSC2)
- 9.3.3 Data Result High Register (ADCRH)
- 9.3.4 Data Result Low Register (ADCRL)
- 9.3.5 Compare Value High Register (ADCCVH)
- 9.3.6 Compare Value Low Register (ADCCVL)
- 9.3.7 Configuration Register (ADCCFG)
- 9.3.8 Pin Control 1 Register (APCTL1)
- 9.3.9 Pin Control 2 Register (APCTL2)
- 9.3.10 Pin Control 3 Register (APCTL3)
- 9.4 Functional Description
- 9.5 Initialization Information
- 9.6 Application Information
- Chapter 10 Internal Clock Source (S08ICSV2)
- 10.1 Introduction
- 10.2 External Signal Description
- 10.3 Register Definition
- 10.4 Functional Description
- Chapter 11 Inter-Integrated Circuit (S08IICV2)
- Chapter 12 Modulo Timer (S08MTIMV1)
- Chapter 13 Real-Time Counter (S08RTCV1)
- Chapter 14 Serial Communications Interface (S08SCIV4)
- Chapter 15 Serial Peripheral Interface (S08SPIV3)
- Chapter 16 Timer Pulse-Width Modulator (S08TPMV3)
- Chapter 17 Development Support
- 17.1 Introduction
- 17.2 Background Debug Controller (BDC)
- 17.3 On-Chip Debug System (DBG)
- 17.4 Register Definition
- 17.4.1 BDC Registers and Control Bits
- 17.4.2 System Background Debug Force Reset Register (SBDFR)
- 17.4.3 DBG Registers and Control Bits
- 17.4.3.1 Debug Comparator A High Register (DBGCAH)
- 17.4.3.2 Debug Comparator A Low Register (DBGCAL)
- 17.4.3.3 Debug Comparator B High Register (DBGCBH)
- 17.4.3.4 Debug Comparator B Low Register (DBGCBL)
- 17.4.3.5 Debug FIFO High Register (DBGFH)
- 17.4.3.6 Debug FIFO Low Register (DBGFL)
- 17.4.3.7 Debug Control Register (DBGC)
- 17.4.3.8 Debug Trigger Register (DBGT)
- 17.4.3.9 Debug Status Register (DBGS)
- Appendix A Electrical Characteristics
- A.1 Introduction
- A.2 Parameter Classification
- A.3 Absolute Maximum Ratings
- A.4 Thermal Characteristics
- A.5 ESD Protection and Latch-Up Immunity
- A.6 DC Characteristics
- A.7 Supply Current Characteristics
- A.8 External Oscillator (XOSC) Characteristics
- A.9 Internal Clock Source (ICS) Characteristics
- A.10 Analog Comparator (ACMP) Electricals
- A.11 ADC Characteristics
- A.12 AC Characteristics
- A.13 FLASH Specifications
- A.14 EMC Performance
- Appendix B Ordering Information and Mechanical Drawings
Chapter 17 Development Support
MC9S08SH8 MCU Series Data Sheet, Rev. 3
278 Freescale Semiconductor
the host must perform ((8 – CNT) – 1) dummy reads of the FIFO to advance it to the first significant entry
in the FIFO.
In most trigger modes, the information stored in the FIFO consists of 16-bit change-of-flow addresses. In
these cases, read DBGFH then DBGFL to get one coherent word of information out of the FIFO. Reading
DBGFL (the low-order byte of the FIFO data port) causes the FIFO to shift so the next word of information
is available at the FIFO data port. In the event-only trigger modes (see Section 17.3.5, “Trigger Modes”),
8-bit data information is stored into the FIFO. In these cases, the high-order half of the FIFO (DBGFH) is
not used and data is read out of the FIFO by simply reading DBGFL. Each time DBGFL is read, the FIFO
is shifted so the next data value is available through the FIFO data port at DBGFL.
In trigger modes where the FIFO is storing change-of-flow addresses, there is a delay between CPU
addresses and the input side of the FIFO. Because of this delay, if the trigger event itself is a change-of-flow
address or a change-of-flow address appears during the next two bus cycles after a trigger event starts the
FIFO, it will not be saved into the FIFO. In the case of an end-trace, if the trigger event is a change-of-flow,
it will be saved as the last change-of-flow entry for that debug run.
The FIFO can also be used to generate a profile of executed instruction addresses when the debugger is not
armed. When ARM = 0, reading DBGFL causes the address of the most-recently fetched opcode to be
saved in the FIFO. To use the profiling feature, a host debugger would read addresses out of the FIFO by
reading DBGFH then DBGFL at regular periodic intervals. The first eight values would be discarded
because they correspond to the eight DBGFL reads needed to initially fill the FIFO. Additional periodic
reads of DBGFH and DBGFL return delayed information about executed instructions so the host debugger
can develop a profile of executed instruction addresses.
17.3.3 Change-of-Flow Information
To minimize the amount of information stored in the FIFO, only information related to instructions that
cause a change to the normal sequential execution of instructions is stored. With knowledge of the source
and object code program stored in the target system, an external debugger system can reconstruct the path
of execution through many instructions from the change-of-flow information stored in the FIFO.
For conditional branch instructions where the branch is taken (branch condition was true), the source
address is stored (the address of the conditional branch opcode). Because BRA and BRN instructions are
not conditional, these events do not cause change-of-flow information to be stored in the FIFO.
Indirect JMP and JSR instructions use the current contents of the H:X index register pair to determine the
destination address, so the debug system stores the run-time destination address for any indirect JMP or
JSR. For interrupts, RTI, or RTS, the destination address is stored in the FIFO as change-of-flow
information.
17.3.4 Tag vs. Force Breakpoints and Triggers
Tagging is a term that refers to identifying an instruction opcode as it is fetched into the instruction queue,
but not taking any other action until and unless that instruction is actually executed by the CPU. This
distinction is important because any change-of-flow from a jump, branch, subroutine call, or interrupt
causes some instructions that have been fetched into the instruction queue to be thrown away without being
executed.
