Datasheet

Chapter 16 Freescale’s Scalable Controller Area Network (S12MSCANV3)
MC9S12XE-Family Reference Manual Rev. 1.25
Freescale Semiconductor 621
NOTE
The CANTFLG register is held in the reset state when the initialization
mode is active (INITRQ = 1 and INITAK = 1). This register is writable when
not in initialization mode (INITRQ = 0 and INITAK = 0).
16.3.2.8 MSCAN Transmitter Interrupt Enable Register (CANTIER)
This register contains the interrupt enable bits for the transmit buffer empty interrupt flags.
Module Base + 0x0006 Access: User read/write
(1)
1. Read: Anytime
Write: Anytime when not in initialization mode; write of 1 clears flag, write of 0 is ignored
76543210
R0 0 0 00
TXE2 TXE1 TXE0
W
Reset: 00000111
= Unimplemented
Figure 16-10. MSCAN Transmitter Flag Register (CANTFLG)
Table 16-13. CANTFLG Register Field Descriptions
Field Description
2-0
TXE[2:0]
Transmitter Buffer Empty — This flag indicates that the associated transmit message buffer is empty, and thus
not scheduled for transmission. The CPU must clear the flag after a message is set up in the transmit buffer and
is due for transmission. The MSCAN sets the flag after the message is sent successfully. The flag is also set by
the MSCAN when the transmission request is successfully aborted due to a pending abort request (see
Section 16.3.2.9, “MSCAN Transmitter Message Abort Request Register (CANTARQ)”). If not masked, a
transmit interrupt is pending while this flag is set.
Clearing a TXEx flag also clears the corresponding ABTAKx (see Section 16.3.2.10, “MSCAN Transmitter
Message Abort Acknowledge Register (CANTAAK)”). When a TXEx flag is set, the corresponding ABTRQx bit
is cleared (see Section 16.3.2.9, “MSCAN Transmitter Message Abort Request Register (CANTARQ)”).
When listen-mode is active (see Section 16.3.2.2, “MSCAN Control Register 1 (CANCTL1)”) the TXEx flags
cannot be cleared and no transmission is started.
Read and write accesses to the transmit buffer will be blocked, if the corresponding TXEx bit is cleared
(TXEx = 0) and the buffer is scheduled for transmission.
0 The associated message buffer is full (loaded with a message due for transmission)
1 The associated message buffer is empty (not scheduled)
Module Base + 0x0007 Access: User read/write
(1)
76543210
R00000
TXEIE2 TXEIE1 TXEIE0
W
Reset: 00000000
= Unimplemented
Figure 16-11. MSCAN Transmitter Interrupt Enable Register (CANTIER)