Datasheet
Chapter 26 384 KByte Flash Module (S12XFTM384K2V1)
MC9S12XE-Family Reference Manual Rev. 1.25
Freescale Semiconductor 993
26.4.2.5 Load Data Field Command
The Load Data Field command is executed to provide FCCOB parameters for multiple P-Flash blocks for
a future simultaneous program operation in the P-Flash memory space.
Upon clearing CCIF to launch the Load Data Field command, the FCCOB registers will be transferred to
the Memory Controller and be programmed in the block specified at the global address given with a future
Program P-Flash command launched on a P-Flash block. The CCIF flag will set after the Load Data Field
operation has completed. Note that once a Load Data Field command sequence has been initiated, the Load
Data Field command sequence will be cancelled if any command other than Load Data Field or the future
Program P-Flash is launched. Similarly, if an error occurs after launching a Load Data Field or Program
P-Flash command, the associated Load Data Field command sequence will be cancelled.
Table 26-40. Read Once Command Error Handling
Register Error Bit Error Condition
FSTAT
ACCERR
Set if CCOBIX[2:0] != 001 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see Table 26-30)
Set if an invalid phrase index is supplied
FPVIOL None
MGSTAT1 Set if any errors have been encountered during the read
MGSTAT0 Set if any non-correctable errors have been encountered during the read
FERSTAT EPVIOLIF None
Table 26-41. Load Data Field Command FCCOB Requirements
CCOBIX[2:0] FCCOB Parameters
000 0x05
Global address [22:16] to
identify P-Flash block
001 Global address [15:0] of phrase location to be programmed
(1)
1. Global address [2:0] must be 000
010 Word 0
011 Word 1
100 Word 2
101 Word 3