Datasheet
Chip Select Module
9-16  MCF5206e USER’S MANUAL MOTOROLA
.
Figure 9-6. Longword Burst Read Transfer from a 16-Bit Port (No Wait States, 
Address Setup, No Address Hold)
Clock 1 (C1)
The burst read cycle starts in C1. During C1, the MCF5206e places valid values on the 
address bus (A[27:0]) and transfer control signals. The transfer type (TT[1:0]) signals 
identify the specific access type and access type and mode (ATM) is driven high to identify 
the transfer as reading code. The read/write (R/W) and write enable (WE[3:0]) signals are 
driven high for a read cycle, and the size signals (SIZ[1:0]) are driven low to indicate a 
longword transfer. The MCF5206e asserts transfer start (TS) to indicate the beginning of 
a bus cycle. The chip select (CS) signal is driven high since the appropriate address setup 
bit in the chip select control register is set to 1.
TS
A[27:0]
R/W
CLK
TT[1:0]
AT M
TA
D[31:16]
TEA
SIZ[1:0]
C1 C2
$0
$0
$ADDR
ATA
CS
WE[3:0]
C3
C4
$ADDR + 2
ADDRESS
SETUP
ADDRESS
SETUP
Fr
eescale S
emiconduct
or
, I
Freescale Semiconductor, Inc.
For More Information On This Product,
 Go to: www.freescale.com
nc...