Datasheet
5-46 MCF5307 User’s Manual
Processor Status, DDATA Definition
Exception Processing PST = 0xC, {PST = 0xB, DD = destination},// stack frame
{PST = 0xB, DD = destination},// stack frame
{PST = 0xB, DD = source},// vector read
PST = 0x5, {PST = [0x9AB], DD = target}// PC of handler
The PST/DDATA specification for the reset exception is shown below:
Exception Processing PST = 0xC,
PST = 0x5,{PST = [0x9AB], DD = target}// PC of handler
The initial references at address 0 and 4 are never captured nor displayed since these
accesses are treated as instruction fetches.
For all types of exception processing, the PST = 0xC value is driven at all times, unless the
PST output is needed for one of the optional marker values or for the taken branch indicator
(0x5).
5.8.2 Supervisor Instruction Set
The supervisor instruction set has complete access to the user mode instructions plus the
opcodes shown below. The PST/DDATA specification for these opcodes is shown in
Table 5-23.
unlk Ax PST = 0x1, {PST = 0xB, DD = destination operand}
wddata.b <ea>y PST = 0x4, {PST = 0x8, DD = source operand
wddata.l <ea>y PST = 0x4, {PST = 0xB, DD = source operand
wddata.w <ea>y PST = 0x4, {PST = 0x9, DD = source operand
1
For JMP and JSR instructions, the optional target instruction address is displayed only for those effective
address fields defining variant addressing modes. This includes the following <ea>x values: (An), (d16,An),
(d8,An,Xi), (d8,PC,Xi).
2
For Move Multiple instructions (MOVEM), the processor automatically generates line-sized transfers if the
operand address reaches a 0-modulo-16 boundary and there are four or more registers to be transferred. For
these line-sized transfers, the operand data is never captured nor displayed, regardless of the CSR value.
The automatic line-sized burst transfers are provided to maximize performance during these sequential
memory access operations.
3
During normal exception processing, the PST output is driven to a 0xC indicating the exception processing
state. The exception stack write operands, as well as the vector read and target address of the exception
handler may also be displayed.
Table 5-23. PST/DDATA Specification for Supervisor-Mode Instructions
Instruction Operand Syntax PSTDDATA
cpushl PST = 0x1
halt PST = 0x1,
PST = 0xF
move.w SR,Dx PST = 0x1
move.w {Dy,#imm},SR PST = 0x1, {PST = 3}
Table 5-22. PST/DDATA Specification for User-Mode Instructions (Continued)
Instruction Operand Syntax PST/DDATA
Fr
eescale S
emiconduct
or
, I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com