Datasheet

Chapter 20. Electrical Specications
20-23
DMA Timing Specications
20.10 DMA Timing Specications
Table 20-14 lists specications for DMA timing parameters shown in Figure 20-22.
Figure 20-23 shows DMA AC timing.
Figure 20-23. DMA Timing
Table 20-15. DMA AC Timing Specifications
Num Characteristic
54 MHz CLKIN
Units
Min Max
M1 DREQ valid to CLKIN (input setup) 7.5 nS
M2 CLKIN to DREQ invalid (input hold) 1.0 nS
M3 CLKIN to DACK valid (output valid) 10 nS
M4 CLKIN to DACK invalid (output hold) 1.0 nS
CLKIN
DREQ
DACK
M1
M2
M4
M3