Information

loading point. If the trigger event was a hardware trigger then the trigger enable bit
(TRIGn) is cleared according to Hardware Trigger. Examples with software and
hardware triggers follow.
system clock
selected loading point
MOD register is updated
write 1 to SWSYNC bit
SWSYNC bit
software trigger event
Figure 37-209. MOD Synchronization with (SYNCMODE = 0), (PWMSYNC = 0), (REINIT =
0), and (Software Trigger Was Used)
system clock
selected loading point
MOD register is updated
write 1 to TRIG0 bit
TRIG0 bit
trigger 0 event
Figure 37-210. MOD Synchronization with (SYNCMODE = 0), (HWTRIGMODE = 0),
(PWMSYNC = 0), (REINIT = 0), and (a Hardware Trigger Was Used)
If (SYNCMODE = 0), (PWMSYNC = 0) and (REINIT = 1) then this synchronization is
made on the next enabled trigger event. If the trigger event was a software trigger then
the SWSYNC bit is cleared according to the following example. If the trigger event was a
hardware trigger then the TRIGn bit is cleared according to Hardware Trigger. Examples
with software and hardware triggers follow.
Functional Description
K10 Sub-Family Reference Manual, Rev. 6, Nov 2011
964 Freescale Semiconductor, Inc.