PDBx_SC field descriptions
Field Description
31–20
Reserved
This read-only field is reserved and always has the value zero.
19–18
LDMOD
Load Mode Select
Selects the mode to load the MOD, IDLY, CHnDLYm, INTx, and POyDLY registers, after 1 is written to
LDOK.
00 The internal registers are loaded with the values from their buffers immediately after 1 is written to
LDOK.
01 The internal registers are loaded with the values from their buffers when the PDB counter reaches
the MOD register value after 1 is written to LDOK.
10 The internal registers are loaded with the values from their buffers when a trigger input event is
detected after 1 is written to LDOK.
11 The internal registers are loaded with the values from their buffers when either the PDB counter
reaches the MOD register value or a trigger input event is detected, after 1 is written to LDOK.
17
PDBEIE
PDB Sequence Error Interrupt Enable
This bit enables the PDB sequence error interrupt. When this bit is set, any of the PDB channel sequence
error flags generates a PDB sequence error interrupt.
0 PDB sequence error interrupt disabled.
1 PDB sequence error interrupt enabled.
16
SWTRIG
Software Trigger
When PDB is enabled and the software trigger is selected as the trigger input source, writing 1 to this bit
reset and restarts the counter. Writing 0 to this bit has no effect. Reading this bit results 0.
15
DMAEN
DMA Enable
When DMA is enabled, the PDBIF flag generates a DMA request instead of an interrupt.
0 DMA disabled
1 DMA enabled
14–12
PRESCALER
Prescaler Divider Select
000 Counting uses the peripheral clock divided by multiplication factor selected by MULT.
001 Counting uses the peripheral clock divided by twice of the multiplication factor selected by MULT.
010 Counting uses the peripheral clock divided by four times of the multiplication factor selected by
MULT.
011 Counting uses the peripheral clock divided by eight times of the multiplication factor selected by
MULT.
100 Counting uses the peripheral clock divided by 16 times of the multiplication factor selected by
MULT.
101 Counting uses the peripheral clock divided by 32 times of the multiplication factor selected by
MULT.
110 Counting uses the peripheral clock divided by 64 times of the multiplication factor selected by
MULT.
111 Counting uses the peripheral clock divided by 128 times of the multiplication factor selected by
MULT.
11–8
TRGSEL
Trigger Input Source Select
Table continues on the next page...
Chapter 34 Programmable Delay Block (PDB)
K20 Sub-Family Reference Manual, Rev. 2, Feb 2012
Freescale Semiconductor, Inc. 675