The capture can occur on rising edges, falling edges or both edges
An input filter can be selected for some channels
In Output Compare mode the output signal can be set, cleared, or toggled on match
All channels can be configured for center-aligned PWM mode
Each pair of channels can be combined to generate a PWM signal with independent
control of both edges of PWM signal
The FTM channels can operate as pairs with equal outputs, pairs with
complementary outputs, or independent channels with independent outputs
The deadtime insertion is available for each complementary pair
Generation of match triggers
Software control of PWM outputs
Up to 4 fault inputs for global fault control
The polarity of each channel is configurable
The generation of an interrupt per channel
The generation of an interrupt when the counter overflows
The generation of an interrupt when the fault condition is detected
Synchronized loading of write buffered FTM registers
Write protection for critical registers
Backwards compatible with TPM
Testing of input captures for a stuck at zero and one conditions
Dual edge capture for pulse and period width measurement
Quadrature decoder with input filters, relative position counting, and interrupt on
position count or capture of position count on external event
35.1.3 Modes of operation
When the MCU is in an active BDM mode, the FTM temporarily suspends all counting
until the MCU returns to normal user operating mode. During Stop mode, all FTM input
clocks are stopped, so the FTM is effectively disabled until clocks resume. During Wait
mode, the FTM continues to operate normally. If the FTM does not need to produce a
Chapter 35 FlexTimer Module (FTM)
K20 Sub-Family Reference Manual, Rev. 2, Feb 2012
Freescale Semiconductor, Inc. 689