Information

FTFL_FCCOBn field descriptions (continued)
Field Description
NOTE: The command parameter table is written in terms of FCCOB Number (which is equivalent to the
byte number). This number is a reference to the FCCOB register name and is not the register
address.
FCCOB Number Typical Command Parameter Contents [7:0]
0 FCMD (a code that defines the flash command)
1 Flash address [23:16]
2 Flash address [15:8]
3 Flash address [7:0]
4 Data Byte 0
5 Data Byte 1
6 Data Byte 2
7 Data Byte 3
8 Data Byte 4
9 Data Byte 5
A Data Byte 6
B Data Byte 7
FCCOB Endianness and Multi-Byte Access :
The FCCOB register group uses a big endian addressing convention. For all command parameter fields
larger than 1 byte, the most significant data resides in the lowest FCCOB register number. The FCCOB
register group may be read and written as individual bytes, aligned words (2 bytes) or aligned longwords
(4 bytes).
28.34.6 Program Flash Protection Registers (FTFL_FPROTn)
The FPROT registers define which logical program flash regions are protected from
program and erase operations. Protected flash regions cannot have their content changed;
that is, these regions cannot be programmed and cannot be erased by any flash command.
Unprotected regions can be changed by program and erase operations.
The four FPROT registers allow 32 protectable regions. Each bit protects a 1/32 region of
the program flash memory. The bitfields are defined in each register as follows:
Program flash protection register Program flash protection bits
FPROT0 PROT[31:24]
FPROT1 PROT[23:16]
FPROT2 PROT[15:8]
FPROT3 PROT[7:0]
Memory Map and Registers