Information

Each CHnF bit in STATUS is a mirror of CHnF bit in CnSC. All CHnF bits can be
checked using only one read of STATUS. All CHnF bits can be cleared by reading
STATUS followed by writing 0x00 to STATUS.
Hardware sets the individual channel flags when an event occurs on the channel. CHF is
cleared by reading STATUS while CHnF is set and then writing a 0 to the CHF bit.
Writing a 1 to CHF has no effect.
If another event occurs between the read and write operations, the write operation has no
effect; therefore, CHF remains set indicating an event has occurred. In this case, a CHF
interrupt request is not lost due to the clearing sequence for a previous CHF.
NOTE
The STATUS register should be used only in Combine mode.
Address: Base address + 50h offset
Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
R
0
W
Reset
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
R
0
CH7F
CH6F
CH5F
CH4F
CH3F
CH2F
CH1F
CH0F
W
0 0 0 0 0 0 0 0
Reset
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
FTMx_STATUS field descriptions
Field Description
31–8
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
7
CH7F
Channel 7 Flag
See the register description.
Table continues on the next page...
Chapter 37 FlexTimer Module (FTM)
K20 Sub-Family Reference Manual, Rev. 1.1, Dec 2012
Freescale Semiconductor, Inc.
Preliminary
851
General Business Information