Datasheet
Field Description Values
T Temperature range (°C) • V = –40 to 105
• C = –40 to 85
PP Package identifier • LQ = 144 LQFP (20 mm x 20 mm)
• MD = 144 MAPBGA (13 mm x 13 mm)
• MJ = 256 MAPBGA (17 mm x 17 mm)
CC Maximum CPU frequency (MHz) • 15 = 150 MHz
N Packaging type • R = Tape and reel
• (Blank) = Trays
2.4 Example
This is an example part number:
MK60FN1M0VLQ15
3 Terminology and guidelines
3.1 Definition: Operating requirement
An operating requirement is a specified value or range of values for a technical
characteristic that you must guarantee during operation to avoid incorrect operation and
possibly decreasing the useful life of the chip.
3.1.1 Example
This is an example of an operating requirement:
Symbol Description Min. Max. Unit
V
DD
1.0 V core supply
voltage
0.9 1.1 V
3.2 Definition: Operating behavior
An operating behavior is a specified value or range of values for a technical
characteristic that are guaranteed during operation if you meet the operating requirements
and any other specified conditions.
Terminology and guidelines
K60 Sub-Family, Rev5, 10/2013.