Table 28. Flexbus full voltage range switching specifications (continued)
Num Description Min. Max. Unit Notes
FB4 Data and FB_TA input setup 13.7 — ns 2
FB5 Data and FB_TA input hold 0.5 — ns 2
1. Specification is valid for all FB_AD[31:0], FB_BE/BWEn, FB_CSn, FB_OE, FB_R/W,FB_TBST, FB_TSIZ[1:0], FB_ALE,
and FB_TS.
2. Specification is valid for all FB_AD[31:0] and FB_TA.
Address
Address Data
TSIZ
AA=1
AA=0
AA=1
AA=0
FB1
FB3
FB5
FB4
FB4
FB5
FB2
FB_CLK
FB_A[Y]
FB_D[X]
FB_RW
FB_TS
FB_ALE
FB_CSn
FB_OEn
FB_BEn
FB_TA
FB_TSIZ[1:0]
Figure 21. FlexBus read timing diagram
Peripheral operating requirements and behaviors
K70 Sub-Family Data Sheet, Rev. 5, 10/2013.
Freescale Semiconductor, Inc. 49