Datasheet
0.90
0.95
1.00
1.05
1.10
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
150 °C
105 °C
25 °C
–40 °C
V
DD
(V)
I
(μA)
DD_STOP
T
J
8.9 Typical value conditions
Typical values assume you meet the following conditions (or other conditions as
specified):
Table 35. Typical value conditions
Symbol Description Value Unit
T
A
Ambient temperature 25 °C
V
DD
3.3 V supply voltage 3.3 V
9 Revision history
The following table provides a revision history for this document.
Table 36. Revision history
Rev. No. Date Substantial Changes
2 9/2012 Completed all the TBDs, initial public release.
3 9/2012 Updated Signal Multiplexing and Pin Assignments table to add UART2
signals.
4 3/2014 • Updated the front page and restructured the chapters
Revision history
Kinetis KL24 Sub-Family, Rev4 03/2014. 51
Freescale Semiconductor, Inc.