Datasheet

2.2 Nonswitching electrical specifications
2.2.1 Voltage and current operating requirements
Table 5. Voltage and current operating requirements
Symbol Description Min. Max. Unit Notes
V
DD
Supply voltage 1.71 3.6 V
V
DDA
Analog supply voltage 1.71 3.6 V
V
DD
– V
DDA
V
DD
-to-V
DDA
differential voltage –0.1 0.1 V
V
SS
– V
SSA
V
SS
-to-V
SSA
differential voltage –0.1 0.1 V
V
IH
Input high voltage
2.7 V ≤ V
DD
≤ 3.6 V
1.7 V ≤ V
DD
≤ 2.7 V
0.7 × V
DD
0.75 × V
DD
V
V
V
IL
Input low voltage
2.7 V ≤ V
DD
≤ 3.6 V
1.7 V ≤ V
DD
≤ 2.7 V
0.35 × V
DD
0.3 × V
DD
V
V
V
HYS
Input hysteresis 0.06 × V
DD
V
I
ICIO
IO pin negative DC injection current—single pin
V
IN
< V
SS
–0.3V
–5 mA
1
I
ICcont
Contiguous pin DC injection current —regional limit,
includes sum of negative injection currents of 16
contiguous pins
Negative current injection
–25 mA
V
ODPU
Open drain pullup voltage level V
DD
V
DD
V 2
V
RAM
V
DD
voltage required to retain RAM 1.2 V
1. All I/O pins are internally clamped to V
SS
through a ESD protection diode. There is no diode connection to V
DD
. If V
IN
greater than V
IO_MIN
(= V
SS
-0.3 V) is observed, then there is no need to provide current limiting resistors at the pads. If
this limit cannot be observed then a current limiting resistor is required. The negative DC injection current limiting
resistor is calculated as R = (V
IO_MIN
- V
IN
)/|I
ICIO
|.
2. Open drain outputs must be pulled to V
DD
.
2.2.2 LVD and POR operating requirements
Table 6. V
DD
supply LVD and POR operating requirements
Symbol Description Min. Typ. Max. Unit Notes
V
POR
Falling V
DD
POR detect voltage 0.8 1.1 1.5 V
V
LVDH
Falling low-voltage detect threshold — high
range (LVDV = 01)
2.48 2.56 2.64 V
Table continues on the next page...
General
6 Kinetis KL24 Sub-Family, Rev4 03/2014.
Freescale Semiconductor, Inc.