Datasheet

Revision History for the MPC5566 Data Sheet
MPC5566 Microcontroller Data Sheet, Rev. 3
Freescale
59
Tabl e 2, Absolute Maximum Ratings:
Deleted Spec 3, “Flash core voltage.”
Spec 12 “DC Input Voltage”: Deleted from second line‘. . .except for eTPUB15 and SINB (DSPI_B_SIN)’ leaving
V
DDEH
powered I/O pads. Deleted third line ‘V
DDEH
powered by I/O pads (eTPUB15 and SINB), including the
min. and max values of -0.3 and 6.5 respectively, and deleted old footnote 7.
Spec 12 “DC Input Voltage”: Added footnote 8 to second line “V
DDE
powered I/O pads” that reads: ‘Internal
structures hold the input voltage less than the maximum voltage on all pads powered by the V
DDE
supplies, if the
maximum injection current specification is met (s mA for all pins) and V
DDE
is within the operating voltage
specifications.
Spec 14, column 2, changed: ‘V
SS
differential voltage’ to ‘V
SS
to V
SSA
differential voltage.’
Spec 15, column 2, changed: ‘V
DD
differential voltage’ to ‘V
DD
to V
DDA
differential voltage.’
Spec 21, Added the name of the spec, ‘V
RC33
to V
DDSYN
differential voltage,’ as well as the name and cross
reference to Table 9, DC Electrical Specifications, to which the Spec was moved.
Spec 28 “Maximum Solder Temperature”: Added two subordinate lines:
Lead free (PbFree) and Leaded (SnPb) with maximum values of 260 C and 245 C respectively.
Footnote 1, added: ‘any of’ between ‘beyond’ and ‘the listed maxima.’
Deleted footnote 2: ‘Absolute maximum voltages are currently maximum burn-in voltages. Absolute maximum
specifications for device stress have not yet been determined.’Spec 26 “Maximum Operating Temperature
Range”: replaced -40 C with T
L
.
Footnote 6 (now footnote 5): Changed to the following sentence to the end, “Internal structures hold the input
voltage greater than -1.0 V if the injection current limit of 2 mA is met. Keep the negative DC voltage greater than
-0.6 V on eTPU[15] and on SINB during the internal power-on reset (POR) state.”
Tabl e 4, EMI Testing Specifications:
Changed the maximum operating frequency to from 132 to f
MAX
.
Footnote 2: Deleted ‘Refer to Table 1 for the maximum operating frequency.’
Table 35. Table and Figure Changes Between Rev. 0.0 and Rev. 1.0 (continued)
Location Description of Changes