Datasheet

NTS0101 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2014. All rights reserved.
Product data sheet Rev. 5 — 11 August 2014 12 of 23
NXP Semiconductors
NTS0101
Dual supply translating transceiver; open drain; auto direction sensing
[1] V
CCI
is the supply voltage associated with the input.
[2] For measuring data rate, pulse width, propagation delay and output rise and fall measurements, R
L
= 1 M. For measuring enable and
disable times, R
L
= 50 K.
[3] V
CCO
is the supply voltage associated with the output.
Test data is given in Table 13
.
All input pulses are supplied by generators having the following characteristics: PRR 10 MHz; Z
O
= 50 ; dV/dt 1.0 V/ns.
R
L
= Load resistance.
C
L
= Load capacitance including jig and probe capacitance.
V
EXT
= External voltage for measuring switching times.
Fig 7. Test circuit for measuring switching times
V
M
V
M
t
W
t
W
10 %
90 %
0 V
V
I
V
I
negative
pulse
positive
pulse
0 V
V
M
V
M
90 %
10 %
t
f
t
r
t
r
t
f
001aal963
V
EXT
V
CC
V
I
V
O
DUT
C
L
R
L
R
L
G
Table 13. Test data
Supply voltage Input Load V
EXT
V
CC(A)
V
CC(B)
V
I
[1]
t/V C
L
R
L
[2]
t
PLH
, t
PHL
t
PZH
, t
PHZ
t
PZL
, t
PLZ
[3]
1.65 V to 3.6 V 2.3 V to 5.5 V V
CCI
1.0ns/V 15pF 50k, 1 M open open 2V
CCO