Datasheet

Analog Integrated Circuit Device Data
48 Freescale Semiconductor
10XSC425
6.4.4.1 Previous Address SOA4 : SOA0 = A
1
A
0
000 (STATR_s)
The returned data OD8 reports logic [1] in case of previous Power ON Reset condition (V
SUPPLY(POR)
). This bit is only reset by
a read operation.
Bits OD7: OD0 reflect the current state of the Fault register (FLTR) corresponding to the output previously selected with the bits
SOA4:SOA3 = A
1
A
0
(Table 23).
OC_s: overcurrent fault detection for a selected output,
SC_s: severe short-circuit fault detection for a selected output,
OS_s: output shorted to V
PWR
fault detection for a selected output,
OLOFF_s: OpenLoad in OFF state fault detection for a selected output,
OLON_s: OpenLoad in ON state fault detection (depending on current level threshold: bulb or LED) for a selected output,
OV: overvoltage fault detection,
UV: undervoltage fault detection
POR: power on reset detection.
The FSB pin reports all faults. For latched faults, this pin is reset by a new Switch OFF command (toggling fault_control signal).
6.4.4.2 Previous Address SOA4 : SOA0 = A
1
A
0
001 (Pwmr_s)
The returned data contains the programmed values in the PWMR register for the output selected with A
1
A
0
.
6.4.4.3 Previous Address SOA4 : SOA0 = A
1
A
0
010 (confr0_s)
The returned data contains the programmed values in the CONFR0 register for the output selected with A
1
A
0
.
6.4.4.4 Previous Address SOA4 : SOA0 = A
1
A
0
011 (confr1_s)
The returned data contains the programmed values in the CONFR1 register for the output selected with A
1
A
0
.
6.4.4.5 Previous Address SOA4 : SOA0 = A
1
A
0
100 (ocr_s)
The returned data contains the programmed values in the OCR register for the output selected with A
1
A
0
.
6.4.4.6 Previous Address SOA4 : SOA0 = 00101 (gcr)
The returned data contains the programmed values in the GCR register.
6.4.4.7 Previous Address SOA4 : SOA0 = 00111 (diagr0)
The returned data OD2 reports logic [1] in case of PWM clock on IN0 pin is out of specified frequency range.
The returned data OD1 reports logic [1] in case of calibration failure.
The returned data OD0 reports logic [1] in case of overtemperature prewarning (temperature of GND flag is above T
OTWAR
).
6.4.4.8 Previous Address SOA4 : SOA0 = 01111 (diagr1)
The returned data OD4: OD1 report in real time the state of the direct input IN[3:0].
The OD0 indicates if the watchdog is enabled (set to logic [1]) or not (set to logic [0]). OD4:OD1 report the output state in case
of Fail-safe state due to watchdog time-out as explained in the following
Table 24.
Table 24. Watchdog Activation Report
WD_en (OD0) SPI Watchdog
0 disabled
1 enabled