User guide
MOTOROLA MPC184/MPC185 Security Co-Processor Software User’s Guide 47
PRELIMINARY—SUBJECT TO CHANGE WITHOUT NOTICE
Global Definitions
4.6.8.6 MOD_CLR_STATIC_REQ
unsigned long opId;
unsigned long channel;
PMPC18x_NOTIFY_ROUTINE notify;
PMPC18x_NOTIFY_CTX pNotifyCtx;
PMPC18x_NOTIFY_ON_ERROR_ROUTINE notify_on_error;
MPC18x_NOTIFY_ON_ERROR_CTX ctxNotifyOnErr;
int status;
void* nextReq;
unsigned long aDataBytes;
Dynamic channels are not valid for this request. A channel value of zero is invalid.
NUM_MM_STATIC_CLR_DESC defines the number of descriptors within the DPD_MM_SA_CLR_GROUP that
use this request.
DPD_MM_SA_CLR_GROUP (0x5A00) defines the group for all descriptors within this request.
Table 36. MOD_CLR_STATIC_REQ Valid Descriptor (opId)
Descriptor Value Function Description
DPD_MM_SA_CLR 0x5A00 Clear the MOD context in a static channel