Datasheet

UBA2037_1 © NXP B.V. 2008. All rights reserved.
Product data sheet Rev. 01 — 30 October 2008 6 of 14
NXP Semiconductors
UBA2037
Full bridge control IC for HID general lighting
7.6 Bridge disable
The bridge disable function can be used to switch off all the MOSFETs as soon as the
voltage on pin BD exceeds the bridge disable voltage V
BD
. The bridge disable function
overrules all the other states.
8. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). All voltages are measured with respect to signal
ground (pin 14); positive currents flow into the chip. The voltage ratings are valid provided other ratings are not violated.
Symbol Parameter Conditions Min Max Unit
General
T
amb
ambient temperature 40 +125 °C
T
j
junction temperature 40 +150 °C
T
stg
storage temperature 55 +150 °C
Voltages
V
VDD
voltage on pin VDD DC 0 14 V
maximum pulse time = 100 ns 0 17 V
V
HV
voltage on pin HV 0 550 V
V
SHL
voltage on pin SHL with respect to PGND and SGND 3 550 V
with respect to SGND;
maximum pulse time = 1 µs
14 550 V
V
SHR
voltage on pin SHR with respect to PGND and SGND 3 550 V
with respect to SGND;
maximum_pulse_time = 1 µs
14 550 V
V
FSL
voltage on pin FSL with respect SHL 0 14 V
V
FSR
voltage on pin FSR with respect SHR 0 14 V
V
GHL
voltage on pin GHL V
SHL
V
FSL
V
V
GHR
voltage on pin GHR V
SHR
V
FSR
V
V
GLL
voltage on pin GLL V
PGND
V
VDD
V
V
GLR
voltage on pin GLR V
PGND
V
VDD
V
V
PGND
voltage on pin PGND 0 5 V
V
SS(CLK)
CLK ground supply voltage t<1s 0 464 V
V
DD(CLK)
CLK supply voltage t<1s 0 464 V
with respect to V
SS(CLK)
:
DC 0 14 V
maximum pulse time = 100 ns 0 17 V
V
I
input voltage pins CLK, SU, BD, and DD; with respect to V
SS(CLK)
:
DC 0 V
VDD
V
maximum pulse time t = 100 ns 0 17 V
pin RC:
maximum pulse time = 100 ns 0 17 V
SR slew rate pins SHL and SHR - 6 V/ns
pin V
SS(CLK)
- 0.5 V/µs