User Manual

-19-
1. Touch it to enter installer setting
interface.
Current addtess [01]
Intercom enable Enable
IPC Setting
Monitor list manage
System settings
Current addtess [01]
Intercom enable Enable
IPC Setting
Monitor list manage
System settings
Setting
Setting
Call Tune
General
Installer
Wireless
About
Call Tune
General
Installer
Wireless
About
Installer setting
This section contains the device address setting and system settings.
DIP Switcher Set Address
The DIP switches are used to set the user code for each monitor.Total 6 bits can
becongured.
• Bit-1 to Bit-5 are used for user code setting. The value range is from 0 to 31,
which have 32 different codes for 32 apartments.
• When multi monitors need to be installed in one apartment, these monitors
should use the same user code, and the master/slave mode should be set on
the monitor. (Details refer to the section of
Setting Slave Monitor
)
• Bit-6 is bus line terminal switch, which should be set to “ON” if the monitor is at
the end of bus line, otherwise be set to “OFF”.
Bit-6 switch setting
ON(1)
=
OFF(0)
=
ON
ON
ON
1 2 3 4 5 6
Bit state Setting Bit state Setting
1 2 3 4 5 6
ON
When monitor
is not at the
end of bus line.
When monitor
is at the end of
bus line.
1 2 3 4 5 6
ON
This monitor is assigned with DIP setting instructions.Total 32 DIP codes.