Installation Guide

- English -
8
Cleaning the quartz glass / Replacing the UVC lamp
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns
Protective measures:
• Never operate the UVC lamp outside its housing.
• Never operate the UVC lamp in a housing that is defective
Danger: Ultraviolet radiation.
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 9 watts:
Warning: To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault circuit
interrupter (GFCI)
For indoor and outdoor household use
Attention! Breakable glass
Possible consequences: Injury to your hands caused by cuts
Protective measures: Handle the quartz glass and UVC lamp with care.
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into the casing.
Opening the UCV clarifying unit
1. Remove the cover from the UVC clarifying unit.
Turn the UVC clarifying unit counter-clockwise up
against the stop (bayonet closure), then carefully
pull out of the lter cover including the O ring.
2. Loosen the self-tapping screw until the the screw tip
is sunk in the housing of the clamping screw.
3. Unscrew the clamping screw counter-clockwise.
4. Remove the quartz glass including the O ring towards
the front with a slight turning movement.
Check the quartz glass and the O ring for damage
and replace, if necessary.
Clean the quartz glass outer face with a moist
cloth.
!
!