Use and Care Manual

12
- English -
Pos: 39 /Alle Produkte/ Überschriften/H1 Reinigung und Wartung @ 7\ mod_1196625212761_121.d oc @ 41469 @
Maintenance and cleaning
Pos: 40 /Lampen/Wasser spieltechnik/W ater-Trio/Quintet/ Reinigung und Wartung W ater Trio/Quintet @ 8\mod_12 19738866712_121.d oc @ 50971 @
Disconnect the power plugs of all other units in the water prior to starting work on the unit (I)!
Cleaning the unit (L, M, N):
To open, release the nozzle holders (9) by slightly turning it at the housing top section (10) and remove
.
Unscrew the LED light nozzles (11) and, if fitted, the extension tubes (6) (see Fig. C).
Laterally slide the respective pump (26) out of the engagement holder of the filter basket (27)
.
Slightly turn the pump cover to disengage (28), then remove the impeller (29).
Clean all components under running water using a brush.
Reassembling the unit:
Reassemble the unit in the reverse order (L, M, N).
Note: Push the pump housing into the filter basket until it tangibly engages.
Pos: 41 /Lampen/Wasserspieltechnik/Water-Trio/Quintet/Batteriewechsel Handsender Water Trio/Quintet @
8\mod_1220013086765_121.doc @ 51409 @
Battery change in the manual transmitter (O, P):
Im
proper handling can lead to damage to the manual transmitter!
Touch a bare metal surface (e.g. a radiator) to discharge static charges, which could lead to damage to the
internal components of the manual transmitter!
Ensure that neither dirt nor moisture can enter the manual transmitter!
Guide a slot screwdriver (30) in
to the lateral opening (31) of the manual transmitter.
Open the manual transmitter housing by slightly turning the screwdriver, then remove the housing bottom secti-
on (32).
Pull the battery (33) out of the holder (34).
Push the new battery into the holder (34). Ensure that the embossed side (35) of the battery points upward.
Pos: 42 /Alle Produkte/ Überschriften/H1 L agern / Überwintern @ 7\mod_ 1196625251745_121.doc @ 41495 @
Storage/Over-wintering
Pos: 43 /Lampen/Wasser spieltechnik/W ater-Trio/Quintet/ Lagern und Überwintern W ater Trio/Quintet @ 8\mod _1223632685324_121.doc @ 54230 @
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the Water Trio / Water Quintet frost protected and submersed in a water filled container. Do not immerse the
plug.
Pos: 44 /Alle Produkte/ Entsorgung - gem. Besti mmungen/Fachhändler @ 0\mod_1125578523312_1 21.doc @ 1407 @
Disposal
Dispose of the unit in accordance with the national legal regulations.
Pos: 45 /Alle Produkte/ Überschriften/H1 S törungsbeseitigung @ 7\ mod_1196625290699_121. doc @ 41521 @
Remedy of faults
Pos: 46 /Lampen/Wasser spieltechnik/W ater-Trio/Quintet/ Störungstabelle W ater Trio/Quintet @ 8\mod_122 3376103151_121.doc @ 54083 @
Malfunction Cause Remedy
Pumps do not start No mains voltage Check mains voltage
Check supply lines
Unit does not respond to manual transmitter Manual transmitter not taught in Teach-in manual transmitter
Impeller blocked or soiled Clean impeller
Pump strainer casing soiled Clean strainer casing
Insufficient fountain height
Nozzles soiled Clean nozzles
Water temperature too high Note maximum water temperature of + 35°C.
For switching on again, pull the power plug and
reinsert in the socket.
Unit switches off after a brief running time
(approx. 10 s)
Pumps run dry Check water level and, if necessary, top up the
water. For switching on again, pull the power
plug and reinsert in the socket.