- Oasis Heating Module Diesel and AC Heating System for Recreational Vehicles and Yachts Installation and Operating Manual

Section 2, Mounting the Oasis™ Heating Module
Combustion air must be drawn from an outside source and
cannot contain any combustible gases.
Oasis™ Heating Module must be mounted in an area that
provides unrestricted access to the front panel. Allow space for
connection to the fuel and coolant lines, as well as the power
and exhaust connections. (Minimum of 10” top clearance - top
exhaust version; minimum of 6” top clearance - bottom
exhaust version; 0” clearance to all other Oasis™ Heating
Module surfaces). Allow 1” clearance on the sides for attaching
the mounting brackets.
Mount the unit with the front panel side facing out and
accessible. Facing out simplifies installation and maintenance.
Oasis™ Heating Module must be mounted horizontal and level
using eight, 1/4” through bolts and 1” diameter fender
washers, lock washers and nuts.
Figure 2-1: Module Dimensions
Oasis™ Heating Module must not be installed or operated in any
compartment with flammable gases.
! DANGER
If the Oasis™ Heating Module is going to be mounted in the engine
compartment, check for adequate ventilation. When the engine is
running this area could be under a negative pressure. Make sure
the air-intake and exhaust hoses have no leaks and are well
fastened to the heater, muffler and thru-hull fitting. Assembly
!
W
ARNING
International Thermal Research 2-3