- Oasis Heating Module Diesel and AC Heating System for Recreational Vehicles and Yachts Installation and Operating Manual

Section 9, Installing the Distribution Module
The Domestic water connections are located on top of the
module. The Cold water supply can be connected using a ½”
NPT fitting. The maximum water supply pressure to the
module is 150 PSI (10 bar). The Hot water Outlet
temperature is regulated by an internal mixing valve factory
set at 120F (49°C). If needed this valve can be adjusted in a
range from 100F (38°C) to a maximum of 145F (63°C). For
more details about adjusting the temperature see chapter
9.9. A domestic water drain is provided for winterizing
purposes. This will prevent damage to the internal heat
exchanger due to freezing water. See Figure 9-4: Domestic
Hot water system plumbing.
All fittings, hose, tube and fitting sealant involving the domestic
water must be food safe and approved for use with domestic
water and rated for the domestic water system pressure.
W
ARNING
Figure 9-4 Domestic Hot Water System Plumbing.
The engine heat/pre-heat connections are located on the
side of the distribution module. Hot coolant from the engine
enters the module at the “engine heat inlet”. The “engine heat
outlet” returns the coolant back to the engine supply. When
the pre-heat function is installed an additional pump is
connected between the “engine heat outlet” and the engine
9-4 The Oasis™ Heating Module