- Oasis Heating Module Diesel and AC Heating System for Recreational Vehicles and Yachts Installation and Operating Manual

Section 9, Installing the Distribution Module
Figure 9-7: Connecting two Heating loops.
Use only a non-toxic propylene glycol based coolant with
additives generally recognized as safe ”GRAS” by the FDA in the
coolant side of the Distribution Module. Refer to the anti-freeze
manufacturer recommendations for instructions for your
particular application.
! DANGER
Do not operate the Oasis™ Heating Module and Distribution
Module, DM12 (Optional) until coolant is in the Oasis™ Heating
Module and Distribution Module and all trapped air has been
bled.
W
ARNING
NOTICE
NOTICE
All plumbing lines must be run and secured so as to prevent
damage, chafing and kinking.
9.5 Filling/Purging the heating system
The Distribution module contains two valves with ½”NPT
connections to be used for filling the heating loop. To initially fill
up and bleed the air out of the system, do the following:
1. Connect a hose to the outlet of a diaphragm pump and to the
“fill inlet valve” on the distribution module. Attach a hose to the
International Thermal Research 9-7