INSTALLATION / OPERATION MANUAL FSTB-A SERIES BREWERS FSTB-A60 *FSTB-A60C Length Height Width FSTB-A80 Length Height Width 20-1/2 16-7/8 9-7/8 20-1/2 21-1/2 10-1/4 1430 Watts 12 Amps 120 Volts 1430 Watts 12 Amps 120 Volts *Model includes carafe OASIS CORPORATION 265 N. Hamilton Road P. O. Box 3150•Columbus, OH 43213-0150 1-800-64-OASIS (1-800-646-2747) www.OasisWaterCoolers.
CAUTION: READ INSTALLATION / OPERATION INSTRUCTIONS PRIOR TO INSTALLING AND OPERATING THE FRESHSTART BREWER INSTALLATION INSTRUCTIONS A. INSPECTION Brewer comes complete with brew basket, detachable power cord and installation/operation manual (carafe may be included, but is sold separately). 1. Inspect the carton and brewer for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier. 2. Remove top cover. 3. Remove float cap assembly from the feed reservoir.
WARNING: WATER TANK MUST BE FILLED BEFORE PLUGGING MACHINE INTO ELECTICAL OUTLET VOLUME PROGRAM PROCEDURE A. ENERGIZE BREWER / HOT TANK HEAT UP 1. To power up brewer and start the hot tank, push the ON/OFF MAIN POWER switch, at rear of the brewer, to the ON position (See Figure 2). ON OFF Figure 2 ON/OFF MAIN POWER switch illustration (switch located at rear of brewer) 2. 3. 4. Turn the front control panel on by pressing the ON/OFF BREW CANCEL button.
OPERATION INSTRUCTIONS A. BREWING COFFEE 1. Remove brew basket from brewer. 2. Place one (1) standard commercial filter (9.5 inch diameter) into brew basket. 3. Put required amount of coffee grounds into filter and shake brew basket to level off coffee grounds. 4. Return brew basket to brewer. NOTE: 5. 6. Place appropriate EMPTY thermal carafe into position below the brew basket. Press the BREW (FULL POT) button for full pot volume or the BREW (HALF POT) button for half pot volume. NOTE: 7. 8.
SERVICE INSTRUCTIONS A. ADJUSTING HOT TANK THERMOSTAT Whenever thermostat adjustment becomes necessary, complete the following procedure: 1. Disconnect power cord from electrical outlet. 2. Remove (2) screws and rear panel (see figure 5). 3. Use a bladed screwdriver to adjust the thermostat knob (see figure 5). Turn clockwise for hotter water temperature and counter clockwise for cooler water temperature. 4. Replace rear panel and (2) screws. 5.
D. SERVICING THE MECHANICAL FLOATS Resetting the Safety Float 1. Remove cover from cabinet. 2. Press down on the safety float re-set button (see figure 8). Float arm inspection 1. Remove float cap from top reservoir. 2. Float arms should move up and down freely and should not bind or catch (see figure 9). E. Safety float re-set button Circuit Board Solenoid Valve Spray Head Tube Figure 8 Open Cover Figure 9 Mechanical Float Cap Assembly INSPECT AND REPLACE CIRCUIT BOARD FUSE 1. 2. 3. 4. 5. F.
G. THERMOSTAT REPLACEMENT (CONTINUED) Limiter Control (see figure 11) 1. Follow steps 1 and 2 from Primary Thermostat. 2. Remove tank feed and vent silicone tubing from reservoir bottom. 3. Remove upper reservoir by releasing the (3) clips. 4. Remove both wires from limiter thermostat. 5. Using a ¼ inch nut driver remove both screws from bracket. 6. Replace limiter control using the reverse order. H.
TROUBLE SHOOTING GUIDE PROBLEM Brew Cycle Will Not Start RESOLUTION • • • • • • • • • • • No Hot Water or Not Hot Enough Hot Water • • • • Carafe Overflows • • • • • • • Weak Coffee • • • Hot Faucet Dripping • • Slow Flow Rate from Hot Faucet • • Dry Coffee Remaining in Brew Basket • • • Check that the power cord is properly plugged into the IEC receptacle located at the back of the brewer (see Figure 5).