Model PWFSBF-K12 (retro fit) Bottle Filler Installation Instructions The Bottle Filler mounts directly above Versacooler® I and II products. No additional electrical connections are required. If installed onto a refrigerated cooler, then chilled water can be dispensed through the Bottle Filler. Otherwise, room temperature water will be dispensed. The Bottle Filler is shipped partially assembled.
Section 1: Getting Started What’s Included: Installation instructions Quick connect tee fitting K-12 Bottle Filler with filter (installed onto the wall frame) 1. 2. 3. Snap bushing One 38” of ¼ OD plastic tubing with 14” of sponge tubing insulation. One 38” of ¼ OD plastic tubing. One 48” of ¼ OD plastic tubing.
Section 2: Rough In Drawing Oasis Versacooler® II Models PGAC, PG8AC with Bottle Filler 3
Section 2: Rough In Drawing Oasis Versacooler® II Split Level Models with Bottle Filler *On split level models, the Bottle Filler must be mounted on the low unit in order to meet ADA guidelines.
Section 3: Installation A: Drilling Hole in the Top for Water Line Connections. 1. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power. 2. Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve. 3. Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE 4. Mark hole location 5. Remove top from unit.
ALIGN THIS EDGE WITH LEFT EDGE OF COOLER TOP Mark this center point on the top. Remove the top from the cooler. Then create a 7/8” diameter hole through the top at the marked center point (step drill bit or punch die).
Section 3: Installation B: Connecting the Water Line If the cooling tank is non-pressurized, then go to the “Pressurizing the cooling tank” addendum section. Otherwise, proceed to step 1 below. Non-pressurized units are single units made since December of 2009. Refer to the schematic below to identify the system that you have. Water valve/ regulator NONPRESSURIZED COOLING TANK 1.
Section 3: Installation: For the P8AC Version: Versacooler II 2. Disconnect tubing from the elbow on the valve. 3. Using the 38” piece of tubing provided, cut 6” and install it on the end of the TEE. Install the remaining tubing onto the branch of the TEE. Connect the other end of the TEE to the tank outlet tubing (tube that was disconnected from the elbow). 32” tubing 6” tubing TEE 4. Route the TEE and tubing under the waste drain and connect the 6” length to the water valve elbow.
Section 3: Installation: For the P8AM Version: Versacooler I 2. Remove tar tape from the insulation on the outlet tube. Remove tar tape 3. 4. Pull back insulation and cut the copper tube with a tubing cutter. Cut where there is at least 1 inch of straight tubing on each side of the cut. Install TEE fitting by connecting the copper tubing to each end. Then install the 32” piece of plastic tubing to the TEE branch.
Section 3: Installation: Final steps for both product families: 5. Feed tubing up through the top and attach the top to the cooler. To activation cartridge inlet. TIP: For the P8AM, it is easier to connect the outlet tube to the bubbler if the front nose is removed.
Section 3: Installation C: Mounting the frame to the wall 1. Set the wall frame onto the top. Center it left/right and push it against the wall and mark hole locations for wall fasteners. The rubber feet will set the frame at the proper height. Make sure to pull the plastic tubing up through the hole in the frame. Use mounting slots that will provide the proper securing location. 2. Secure frame to the wall with fasteners (not provided). Pull plastic tubing up through the hole in the frame.
Section 3: Installation D: Bottle Filler Plumbing Connections 3.1. Install water line tubing as shown below. ATTENTION: Shut off water and relieve water pressure through bubbler. Supply water line In Filtered water out to cold tank 48” (trim excess) Cold water out with sponge tubing to activation cartridge inlet. 38” Activation Cartridge Cold water out of cooling tank. Front view of cooler & bottle filler. Cut cold water out tubing and insert tee fitting before valve cartridge holder inlet.
Section 3: Installation 3.2. Install water line tubing as shown below. ATTENTION: Shut off water and relieve water pressure through bubbler. Filtered water out to cold tank 48” (trim excess) Supply water line In Activation Cartridge Cold water out (existing) Cold water out with sponge tubing to activation cartridge inlet. 38” Front view of cooler & bottle filler. Cut cold water out tubing and insert tee fitting before valve cartridge holder inlet.
Section 3: Installation E: Attaching the Tether 4. Install bottle filler tether with the steps below. Attach the tether line assembled to the bottle filler dispense bracket to the cleat on the mounting frame. 1. Push loop through hole. 3. Pull loop around other side of the cleat. 2. Put loop around one side of the cleat. 4. Pull tight.
Section 3: Installation The tether keeps the bottle filler secured to the frame when changing the filter. Make sure the tether is installed properly to avoid accidental damage to the unit.
Section 3: Installation F: Attaching Bottle Filler to Frame 5. Set the Bottle Filler cabinet into place. 6. Attach Bottle Filler assembly to the frame using the two (2) torx screws.
Section 3: Installation G: Installation Completion 7. Turn ON water supply and check for leaks. Press the activation button and release any trapped air from the system. Plug in the power cord and replace the front panel IF it was removed earlier. Flush out filter as directed on the filter cartridge label.
Addendum Section: Pressurizing Cooling Tank The water should already be turned OFF and the power disconnected. Unit as it appears with top removed STEP 1 Unplug un-insulated water line from water valve inlet (JG elbow located left side of water valve facing the front of the cooler). Set tubing aside (careful to not contaminate water contact end). STEP 2 Unplug tubing from JG elbow leading to cooling tank inlet.
STEP 3 Plug un-insulated tubing that was removed in step 1 into JG elbow leading to the cooling tank from step 2. STEP 4 Unplug tubing that is connected to the water valve outlet (JG elbow located on the right side of valve facing the cooler). STEP 5 Connect tubing from step 4 to JG elbow on the left side of the valve.
Step 6 Unplug JG tubing from the cooling tank outlet. Do not set it down. Step 7 Using tubing removed in step 6, plug into JG elbow on the right side of the valve. (be sure to rout the tubing under existing tubing installed in step 4 as shown) Step 8 Using tubing that is connected to the JG elbow left side of valve (done in step 4), and plug the other end to the JG fitting at the top of the cooling tank.
EXPLODED PARTS BREAKDOWN ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 QTY 1 1 1 2 1 2 1 1 1 1 1 2 1 11'' 12" 2 38" 14" 1 P/N 041080-001 036790-001 038031-009 026642-023 038031-010 031875-003 038636-001 038678-001 035990-001 A020957 029967-005 026670-008 041075-001 028476-001 029959-006 028481-101 029959-006 028476-001 036687-003 Description CABINET, K12 BF BADGE, OASIS SMALL OVAL LABEL, CABINET BUTTON SCREW, HEX HD TAPPING #8 LABEL, ALCOVE SBF K12 SCREW, TRUSS HD TAPPING TORX PUSH BUTTON, AMC PL