Installation Guide

How To Solvent Weld
Prior to Use:
Read all product labels carefully.
Stir or shake cement before using. If gelled, do
not use. Keep container closed when not in use.
Avoid eye and skin contact. Wear safety glasses
with side shields and wear rubber gloves.
1. Cut pipe ends square. Deburr the inside and
chamfer the outside of pipe ends. Remove all dirt
from pipe ends and tting hubs.
2. Interference t between pipe and tting hub
must be completed prior to primer and cement
application. Pipe should easily go 1/3 to 2/3 the
way into the tting hub.
3. Choose suitable applicator at least 1/2 the size of
the pipe diameter. For larger pipe diameters, use
a natural bristle brush or roller.
4. Clean pipe and tting hub with a listed cleaner.
5. First, apply primer inside the tting hub. Then,
apply primer to the exterior of pipe end. Finally,
apply primer inside the tting hub once again.
Once the primer has been applied to both
surfaces, the cement must be applied
within 5 minutes. If not, you MUST prime
the surfaces again before applying cement.
Do not use primer on ABS pipe and ttings.
6. First, apply a liberal coat of cement to the exterior
of the pipe end beyond the depth of the tting hub.
Then, apply cement to the inside of the tting hub.
Finally, apply cement to the exteror of the pipe end
once again.
• Remember that a thin coating of cement
is recommended inside the tting hub to
prevent puddling. Puddling can cause
weakening and lead to joint failure.
• Assemble parts QUICKLY. Cement must be
uid. Dried cement CANNOT be re-coated.
7. Turn pipe 1/4 turn as you push the pipe end into the tting hub.
8. Make sure pipe end bottoms out inside the tting hub and hold for 30 seconds to prevent push-out. Wipe
off excess cement.
• Lower temperatures and larger diameter pipes may need a little extra hold time.
Allow 15 minutes for good handling strength and 2 hours cure time at temperatures above 60°F
before pressure testing up to 180 psi. Longer cure times may be required at temperatures below
60°F or with pipe above 3 in.. DO NOT TEST WITH COMPRESSED AIR OR GAS.
HOW TO
SOLVENT WELD
WITH SOLVENT CEMENTS
4
6
8
1 2
3
5
7
Solvent Cements for any
Application
If you need to solvent weld one pipe joint or
one thousand, Oatey is the solvent cement
more professionals choose than any other
brand. From hot to cold, wet to dry, Oatey
has the solvent cement to meet your exact
requirement for any plastic pipe installation.
Pipe Types
CPVC: Chlorinated Poly Vinyl Chloride
Typically used for pressure piping
applications, including hot and cold
potable water distribution. Can also
be used for corrosive uid handling in
industrial or chemical applications.
ABS: Acrylonitrile Butadiene Styrene
Typically used for non-pressure piping
applications.
PVC: Poly Vinyl Chloride
Typically used for pressure or
non-pressure piping applications.
Product Development
Oatey Solvent Cements are developed with
the plumbing contractor in mind. Extensive
research and product development provide
you peace of mind and condence when
using Oatey brand solvent cements. In
addition, no company works as hard as
Oatey on behalf of the professional plumber
with regulatory and coding agencies.

Summary of content (2 pages)