User Manual

Figure 5 – Snap the Firestop Grommet around the Data Cable and pull through the Conduit Connector as shown.
Figure 4
Step 5 Run the data and power cable (if required) through the
conduit connectors which have been installed in sides of the
access point enclosure. In order to maintain a separation of
signal and power, install the data and power cables through
opposite sides of the enclosure. Snap the fire stop grommet
around the cable and insert it into the conduit connector and pull
the data cable through far enough to allow attachment to the
access point (8" - 10"). Attach any additional data cables as
necessary and power up the networked devices.
Step 6 (For Wall Installation Only) Model 1028-08-ANT5-B
requires at least 8” of free space above the ceiling or behind the
wall to allow for clearance. The Anchoring points on the flange
are 16" apart. For wall installation, cut a 14” X 18” hole.
Additional clearance and bracing may be necessary. Use
appropriate hardware to secure the enclosure. Drywall anchors
and cinderblock anchors may be used.
Step 7 If stud spacing permits, position the enclosure so that
the mounting holes are centrally located with the studs. For metal
studs, use #10 sheet metal screws (or, for wood studs, use #10
wood screws). The screws should be a minimum of 2" in length.
Make sure that the screw is inserted directly into the stud.
Securely tighten the screws after inserting them through the
screw snap cap washer, and be sure that the screw is inserted
directly into the joist. Press the provided screw snap caps onto
the screw head. Alternatively, if no studs are available for
mounting, drywall anchors or cinderblock anchors may be used.
Be sure to use appropriate hardware for the wall construction
type. (Reference Figure 4)
** IMPORTANT** - This is an important safety
feature that could prevent human injury or damage to
the equipment should the unit become dislodged from
the ceiling.
Step 8 (For Ceiling Installation Only) Use hanger wires (included) to support the enclosure. Attach one end of the wire to the mounting
brackets located along the edge of the back box and the other end to a permanent structural component of the building such as a joist. Two
supporting grid wires should be attached to each corner. Reference Oberon’s OPA 1638 drawing (at
http://oberonwireless.com/WebDocs/OPA-1638-10.pdf). For ceiling installation, cut a 18” tall X 14” wide rectangular hole. If space permits,
position the enclosure so that the mounting holes are centrally located with the joists. For metal joists, use #10 sheet metal screws (or, for
wood joists, use #10 wood screws). The screws should be a minimum of 2" in length. Securely tighten the screws after inserting them
through the screw snap cap washer, and be sure that the screw is inserted directly into the joist. Press the provided screw snap caps onto
the screw heads.
Step 9 – Close and lock the access door. Extra force may be necessary to compress the gasket. The installation is now completed.
NOTE: Additional sealing precautions around edges of the enclosure may be necessary.
Page 4
MODEL 1028-08-ANT5-B
Installation Instructions
**** WARNING ****
Please thoroughly read the product warning below before
installation to provide for a safe work environment.
1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical
Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or
other means must be used for the installation of this product in the ceiling. Acoustical, suspended, false, drop and
concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with
independent support wires, wire rope, threaded rod, or other secure support means of adequate gauge and fire
resistance.
2. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door
from accidentally swinging open.
3. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.
4. This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not
exceed this temperature, depending on power dissipation within enclosure.
5. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be
maintained for the safe operation of the equipment.
6. This product is intended to be installed by trained personnel.
7. Only Listed ITE products and Listed AC Receptacles shall be installed within the enclosure.
8. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or
replacement.
9. Maximum weight to be installed in the unit is 44 lbs.
10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that
complies with UL 2043 or UL 1479.
11. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.
12. If AC power is used inside the enclosure, connect the ground wire to the green ground screw located near the
knockout in the backbox.
Page 1