Installation and Activation
Guide Version: 2020.
Installation and Activation Guide Version 2020.1 Last Revision: 2021-06-03 Objectif Lune, Inc. 2030 Pie-IX, Suite 500 Montréal, QC, Canada, H1V 2C8 +1 (514) 875-5863 www.objectiflune.com All trademarks displayed are the property of their respective owners. © Objectif Lune, Inc. 1994-2021. All rights reserved. No part of this documentation may be reproduced, transmitted or distributed outside of Objectif Lune Inc. by any means whatsoever without the express written permission of Objectif Lune Inc.
Table of Contents Table of Contents 6 System and Hardware Considerations 9 Antivirus Exclusions Directories and folders Database Considerations Using the MySQL Instance from the Installer Installing / Updating Connect using an existing MySQL instance Installing Connect using an existing Microsoft SQL Server instance Updating With No Local MySQL Product When modifying Connect Important Environment considerations Terminal Server/Service Support Virtual Machine Support Remote Desktop Support 32-bit or 64-b
Requirements for individual Connect modules Editions of Connect Products Installation and Activation 26 26 27 Where to obtain the installer Installation prerequisites User accounts and security Installing PrintShop Mail Connect on Machines without Internet Access Updating Connect Initial Connect Installation Installation Wizard Updating from Connect versions predating 2019.
Settings Configure engine options Buttons Parallel Processing preferences 57 57 61 62 Parallel Processing properties Preset selection Content Creation Tab Buttons Known Issues 62 62 62 63 64 Issues running Connect on Hyper-V 9.0 The Update Client OL for Connect 2019.
System and Hardware Considerations There are a variety of considerations to be aware of.
Antivirus Exclusions The information on this page is designed to assist IT managers and IT professionals decide what anti-virus strategy to follow with consideration to PrintShop Mail and their internal requirements and needs. This page describes the mode of operation and the files and folders used by PrintShop Mail as well as the files, folders and executables that are recommended to be ignored for best possible performance and to avoid issues caused by antivirus file locks.
l l %USERPROFILE%\Connect\temp: Storage folder for temporary data, usually intermittent files in multiple folders. Virus protection on this folder and its subfolders may have a serious impact on the performance of Connect. %USERPROFILE%\Connect\workspace: Usually containing settings and helper files and folders. Supervising this folder with a virus protection system should not have too much of an impact on the speed of the whole Connect suite.
These are the specific options that have been changed in our version of "my.ini": l l l max_connections = 200 : PrintShop Mail Connect uses a lot of database connections. This number ensures that even in high volume environments, enough connections will be available. max_allowed_packet = 500M : In some implementations, especially when using Capture OnTheGo, large packet sizes are required to allow transferring binary files.
but the supplied MySQL database. Options available within the installer: l l l The Configuration page for the local MySQL is displayed. MySQL settings are pre-filled with default values if no existing MySQL database configuration is found. MySQL settings are pre-filled with existing database configuration settings, if they point to a MySQL database type.
l l l When MS SQL is selected, the default values for root user are sa and 1433 for the port. If database settings from a previous OL Connect installation are found, the pre-exising settings will be displayed for the matching database type. For MS SQL settings, this will only work if they were created with Server Config Tool 1.5.0 or later, or the Installer for OL Connect 1.6.0 or later.
Note The Microsoft SQL selection capability will be available only with 1.6 version and upwards. To remove this dependency the user needs to do the following 1. Have a foreign Microsoft SQL running, ready for use with Connect Server. 2. Use the Server Configuration Tool Database Connection preferences to switch the database to Microsoft SQL. 3. Re-start the Connect Server Service, so that the modifications become active. 4. Counter check that everything is working properly with Microsoft SQL. 5.
Important If a Server Product and a MySQL Product were selected to be installed on Connect 1.5.0, and then the Server Configuration Tool is used to switch the database used by the Server to an external Microsoft SQL, then the Update to 1.6 requires an extra step. The procedure is as follows: 1. Run the Update to Connect 1.6.
Virtual Machine Support PrintShop Mail Connect supports the following virtual environments: l l l VMWare Environments. This includes VMWare Player, VMWare Workstation as well as VMWare ESX Server. VMWare VMotion. This means the virtual machine hosting PrintShop Mail Connect can be automatically moved from one ESX server to another in a clustered installation.
32-bit or 64-bit Operating Systems? PrintShop Mail Connect is a 64-bit software and can only be installed on 64-bit operating systems. Antivirus Considerations l l Antivirus software may slow down processing or cause issues if they are scanning in temporary folders or those used by PrintShop Mail Connect. Please see "Antivirus Exclusions" on page 10 for more information. Antivirus software might interfere with installation scripts, notably a VBS script to install fonts.
entries and command-line switches are accepted, when one of Connect components is started and run. Please be therefore advised, that any non-whitelisted ini entry or command-line switch will be accepted and will - if tried to be used - lead to the respective application’s “sudden death”. If you should encounter such a behaviour then please double-check your Connect log file/s for respective entries.
Network Considerations The following should be taken into consideration in regards to network settings and communications l If a local proxy is configured (in the Internet Explorer Options dialog), the option Bypass proxy server for local addresses must be checked, or some features depending on local communication will not work. Firewall/Port considerations The following describes all of the ports that can be used by an OL Connect solution.
Listens on port Destination # port # Email Input plugin Secure Email Input plugin Send Email plugin Secure Email Output plugin LPR LPD Telnet FTP Input/Output MySQL Microsoft SQL Server HyperSQL Type 110 TCP 993 TCP 25 TCP 587 TCP 515 TCP TCP TCP 21 TCP 515 9100 3306 TCP+UDP 1433 TCP+UDP 9001 TCP Comment Default POP3 port Default SMTP port l Port numbers in bold type are user configurable. l Port numbers in bold underlined type are based on the type of database used.
Performance Considerations This page is a guide to getting the most performance out of PrintShop Mail Connect as well as a rough guideline to indicate when it's best to upgrade. Performance analysis details In PrintShop Mail Connect, after each print job, a message dialog displays a print job summary (see Print Job Summary dialog). This summary may help you determine how best to maximize the performance of PrintShop Mail Connect.
Template optimization When you find that the speed per Merge engine - the Content Creation speed - is low, optimizing a template can make a huge difference. For advice on how to optimize a template see: Optimizing a template. Network and internet connections Use a fast network and internet connection or avoid loading external or internet resources. Using images, JavaScript or CSS resources located on a slow network or on a slow internet connection will obviously lead to a loss of speed.
cores is low, it makes sense to see if that can be increased. When running on a virtual machine, this is usually easy. When running on a physical machine, it means that you may have to switch hardware. l For both virtual and non-virtual environments, make sure the machine is not busy with all kinds of other processes. System requirements These are the system requirements for PrintShop Mail Connect 2020.
Minimum hardware requirements As with any software application, minimum hardware requirements represent the most basic hardware on which the software will run. Note however that settling for the minimum specification is unlikely to produce the performance you expect from the system. It can be used when configuring a trial or a development system, however.
Requirements for individual Connect modules OL Connect Products comprises multiple modules that can be operated separately on multiple PCs. Each module has its own set of requirements that may differ from the other modules. While the hardware requirements described above are relatively generic when installing all Connect modules on a single server, they should not be interpreted literally for each individual module.
Installation and Activation This topic provides detailed information about the installation and activation of PrintShop Mail Connect 2020.1. Note A PDF version of this guide is available for use in offline installations. Click here to download it. Where to obtain the installer The installer for PrintShop Mail Connect 2020.1 can be obtained on DVD or downloaded as follows: l l If you are a Customer, the installer can be downloaded from the Objectif Lune Web Activation Manager (https://www.objectiflune.
Installation - "How to" guides For information on how to conduct the installation itself, choose from the following topics: l "Installation Wizard" on page 31 l "Running Connect installer in Silent Mode" on page 36 l "Installing PrintShop Mail Connect on Machines without Internet Access" on the next page Activation For information on licensing, please see "Activating a License" on page 44. Installation prerequisites l l l l l Make sure your system meets the System requirements.
The following links contain the details as to when and where Windows Administrator rights are required: l Connect Installation: Connect Installation l Activating Connect: Activating a License Permissions for PrintShop Mail Connect Designer PrintShop Mail Connect Designer does not require any special permissions to run besides that of a regular program. It does not require administrative rights and only needs permission to read/write in any folder where templates are located.
When a machine hosting the installation does not have access to the Internet, the installation will fail because the verification cannot be performed. To solve this problem one must first ensure that all Windows updates have been installed on the host machine. Once the Windows updates are confirmed as being up to date, then complete the following steps: 1. Go to https://certs.godaddy.
1. Open the “Internet Options” via the Control Panel 2. Select the “Advanced” tab and scroll down to “Security” node. 3. Uncheck the entry “Check for publisher’s certificate revocation” under that node. 4. Click the OK button to close the dialog. 5. Re-start the computer. Installation Wizard Updating from Connect versions predating 2019.1 In order to update PrintShop Mail Connect to 2020.1 from Connect versions prior to 2019.1 it is first necessary to update the Connect License.
the following command line options: l l PrintShop Mail_Connect_Setup_x64.exe --verbose This adds extra debugging style logging to the installation process. PrintShop Mail_Connect_Setup_x64.exe --trace This adds full trace style logging to the installation process. The log file this produces will be very large, as this option logs everything.
any but the supplied MySQL database. See "Database Considerations" on page 11 for more information about setting up external databases. l Installation Path: This is the location where modules are to be installed. Note To cater for MySQL requirements, the installation path cannot contain any non ASCII characters (such as Asian language Unicode characters). Nor can it contain characters that Windows disallows in filenames (such as '?', ''>' or trailing spaces).
Configuring Supplied Database Connection The Default Database Configuration page appears if the supplied MySQL module was selected for installation in the Product Selection screen. It defines the administrative password for the MySQL server as well as which port it uses for communication. The installer will automatically configure the Connect Server to use the supplied password and port. l MySQL user 'root' Password: Enter the password for the 'root', or administration account, for the MySQL server.
Note The MySQL database controlled by the OLConnect_MySQL service communicates through port 3306 by default. Click Next to display the Selection Confirmation page. Selection Confirmation This page confirms the installation selections made. Click Next to start the installation itself. This process can take several minutes. Completing the installation This screen describes a summary of the components that have been installed. l l l Configure Update Check checkbox: This option is enabled by default.
Note If the Product Update Manager was already installed by another Objectif Lune Inc. application, it will be updated to the latest version and will retain the settings previously specified. Select the desired options and then click OK to query the server and obtain a list of any updates that are available for your software. l l Note that the Product Update Manager can also be called from the “Objectif Lune Update Client” option in the Start menu.
located either in the same folder as the PrintShop Mail_Connect_Setup_x86_64.exe or in the unpacked folder of the installer.exe. Note Only the installation can be run silently. Silent Mode does not apply to uninstalling, modifying, or updating Connect. Any previous version of Connect must be uninstalled before using the Silent Installer (see: "Uninstalling" on page 75). The required properties file has the following attributes: l Comment Lines, starting with # (e.g.
server.runas.password = admin # Database configuration database.type = mysql database.host = 192.168.116.10 database.port = 3308 database.username = root database.password = admin database.schema = my_ol Verbose logging (optional) By default, the Silent Installer will log the same way as the GUI installer. That means logging of error and warnings, and certain information during database configuration. A more verbose logging can be switched on by using logging.verbose = true.
Server Extension configuration (required if Server Extension is selected for install) For Server Extension, the following properties need to be provided: server.runas.username = server.runas.password = server.master.host = server.master.port = server.master.authenticate = true or false server.master.username = server.master.
Note The port will be defined automatically for the MySQL installation. All connect products selected in the Silent Installer will automatically be configured to use the MySQL running under the port defined by the database.port property, regardless of the default port 3306 or any other user defined port. A different port is required if 3306 is already taken on that machine by another application.
database.type = Microsoft SQL Server (required) database.host = (default value is localhost, otherwise required) database.port = (default value is 1433, otherwise required) database.username = (default value is sa, otherwise required) database.password = (required) database.
Locales supported by Connect The Connect Setup supports a dedicated list of Locales, which is saved in the preinstall.ini file.
user.language = no, will result in an error Default Locale selection If neither user.language nor user.country is defined in the install.properties file, the Installer will select a default Locale: 1. If the System Locale is in the list of supported Locales, it will be selected. 2. Otherwise, if there is an entry in the list of supported Locales, which matches the System language, it will be selected (e.g. on a fr-CA system, fr-FR is selected). 3. As last resort, the first Locale in the preinstall.
10 = General Error in Installer application (for reason see OL_Install_.log) Sample batch file @echo off preinstall.exe if errorlevel 10 goto err_installer if errorlevel 2 goto err_unknown if errorlevel 1 goto err_preinstall echo Success goto:eof :err_installer echo "Installer error - see OL_Install_.log" goto:eof :err_unknown echo "Unknown preinstall error - see preinstall_err.log" goto:eof :err_preinstall echo "Preinstall error - see preinstall_err.
To get the PrintShop Mail Connect Magic Number open the Connect Software Activation application. l Open the Start Menu l Click on All Programs and browse to the Objectif Lune folder. l Open the Connect Software Activation shortcut. l The PrintShop Mail Connect Software Activation application consists of the following: l License Information subsection: l l l Magic Number: Displays the PrintShop Mail Connect Magic Number.
Even if a license file has been Loaded, it will not be installed if this dialog is Cancelled before the Install License button was clicked. Requesting a license After getting the Magic Number, a license request must be done for PrintShop Mail Connect: l l Customers must submit their Magic Number and serial number to Objectif Lune via the Web Activations page: http://www.objectiflune.com/activations. The OL Customer Care team will then send the PrintShop Mail Connect license file via email.
l Click Install License to activate the license. The license will then be registered on the computer and you will be able to start using the software. Warning After installation message will appear warning that the Server services will need to be restarted. Just click OK to proceed. Migrating to a new workstation The purpose of this document is to provide a strategy for transferring a Connect installation to a new workstation. The following guide applies to OLConnect v1.x/201x.x .
Backing up files from the current workstation The first step in migrating to a new workstation would be to make sure all necessary production files and resources are backed up and copied over to the new system. Note Although it is not necessary to convert all of your documents when upgrading to the latest version, we strongly recommended doing so. It is considered "Best Practice" to convert the documents to the version installed.
Tip Actually, the path may not begin with 'C:\Users', as this is language-dependent. On a French system, for example, it would be 'C:\Utilisateurs'. Type %userprofile% in a Windows File Explorer and press Enter to open the actual current user's home directory. Other Resources l l l l OL Connect Designer Templates or Package files, copied from the folder where they reside. All PostScript, TrueType, Open Type and other host based fonts used in templates must be reinstalled on the new workstation.
4. Import the following files and folders from the old server into their equivalent location on the new server: C:\ProgramData\Objectif Lune\PlanetPress Workflow 8\PlanetPress Watch\capture\PPCaptureDefault.mdb C:\ProgramData\Objectif Lune\PlanetPress Workflow 8\PlanetPress Watch\DocumentManager C:\ProgramData\Objectif Lune\PlanetPress Workflow 8\PlanetPress Watch\PGC 5.
l l Configure the DataMapper, Merge and Weaver engines preferences (see "Parallel Processing preferences" on page 62). As of version 2018.1 these preferences include the minimum (Xms) and maximum (Xmx) memory utilization for the Merge and Weaver engines . Configure any other options for the Clean-up Service. 3. If the version used on the new machine is 1.8/8.
load to identify points of improvement and make sure the output matches the user’s expectation. Output generated at this point will normally bear a watermark which can be removed by transferring licenses from the old server to the new one. l l l To transfer Connect and Workflow licenses, the user is usually required to complete a License Transfer Agreement which can be obtained from their local Customer Care department.
To apply the PlanetPress Capture License: 1. Open the Workflow Configuration. 2. Click on Help on the Menu Bar and click on PlanetPress Capture License manager to import your license. Uninstalling PrintShop Mail Connect from the previous workstation It is recommended to keep the previous install for a few days until everything is completed. However, once your transition is successful and complete, the OL Connect software must be uninstalled from the original server. See "Uninstalling" on page 75.
Note The scheduling settings in version 2019.2 have changed. Please make sure to record your current scheduling settings for reference before proceeding with an upgrade. Users of Connect prior to 2019.1 Users of all Connect versions prior to 2019.1 should note that Update Client 1.2.40 is a prerequisite for both OL Connect 2019.1 and Connect Workflow 2019.1 installations. Only Update Client 1.2.
Whilst the probability of such a worst case scenario is remote, it cannot hurt to take some simple precautions, just in case. Backing up a virtual machine Backing up a virtual machine installation is relatively straight forward. Simply take a snapshot of the virtual machine instance, prior to upgrading. This would save all the localized preferences and configurations. Backing up a real machine Note The scheduling settings in version 2019.
French system, for example, it would be 'C:\Utilisateurs'. Type %userprofile% in a Windows File Explorer and press Enter to open the actual current user's home directory. Backup your database If you want to be completely thorough and be able to exactly replicate your existing system, you should also backup your existing Connect database. If the default MySQL database is being used as the Connect back-end database, we would recommend the MySQLDump tool be used for this.
Engines preferences Background A Merge engine merges the template and the data to create Email output, or to create an intermediary file for Printed output. The intermediary file is in turn used by a Weaver engine to prepare the Print output. This page appears in the Designer Window > Preferences dialog. It allows control over Merge and Weaver (output) engines. Settings Configure engine options l Tasks handled by: Select how Connect jobs are to be processed.
Number of engines This group is only available if Engines were selected as the processing architecture . l Merge Engines selection: Select the desired amount of Merge Engines. A Merge engine merges the template and the data to create Email output, or to create an intermediary file for Printed output. The intermediary file is in turn used by a Weaver engine to prepare the Print output.
l Weaver Engines selection: This option is read-only in PrintShop Mail Connect Designer Preferences. Select the desired amount of Weaver (Output) Engines. A Merge engine merges the template and the data to create Email output, or to create an intermediary file for Printed output. The intermediary file is in turn used by a Weaver engine to prepare the Print output. Adding extra Weaver (Output) engine(s) might be useful when large Print jobs are to be run simultaneously with smaller Print jobs.
l l l DataMapper engines may perform better with greater memory when running jobs containing a lot of data. For complex templates with a lot of pages per document, there is a chance that Merge engines will run better with more memory. The maximum memory usage of a Weaver engine can be relevant for jobs with heavy graphics; or for jobs that use Cut & Stack impositioning; or for jobs using particular variables that entail page buffering (see Content variables).
l Number of multi-threaded form rips selection: Set the amount of individual threads to assign to form ripping. This setting is useful for when graphics content triggers rasterization when writing AFP or IPDS output. Typical examples of content triggering rasterization are: transparency; fill patterns; gradient fills; or text rotated at a non-right angle. Increasing the number of threads should speed up Output Creation under such circumstances.
Parallel Processing preferences The parallel processing preferences (previously referred to as Scheduling preferences, prior to 2019.2) page provides the means to control precisely how the PrintShop Mail Connect Designer handles jobs that operate in parallel. For additional information on how these preferences can enhance performance, see Engine configuration and "Performance Considerations" on page 22.
number, not because it has been proven to have any significant value. It means that on an average system (i.e., less than 10 Merge engines) any decently sized task is allowed to use all Merge engines. It also assumes that using more than one Merge engine for less than 100 records will probably not make a big enough difference to throughput speed. Obviously, there are situations where these assumptions will not apply.
Known Issues This page lists important information about issues that apply to PrintShop Mail Connect 2020.1. Issues running Connect on Hyper-V 9.0 Some customers have reported difficulties running OL Connect on Hyper-V version 9.0. In some instances Connect cannot install and in others the Connect Server service sometime stops with a signature error. To resolve these issue we recommend downgrading to Hyper-V version 8.0 where these issues are not reported.
To workaround this issue, we recommend downloading and manually installing the latest Visual C++ Redistributable from https://support.microsoft.com/en-ca/help/2977003/the-latestsupported-visual-c-downloads then re-running the Connect 2019.2 installation. Issues associating PDF files with Connect Under certain circumstances, Connect Setups prior to 2019.2 would fail when attempting to add the "Enhance with Connect" association with PDF files. This would then cause the setup to appear to fail.
The Update Client OL for Connect 2019.1 does not cater for standalone Connect Print Manager installations The Connect Print Manager is a standalone Connect tool that is used in production sites to manage print jobs. It can be installed and run on standalone machines without a Connect license. The Update Client for Connect 2019.1 looks for a Connect license as part of the update process, but it will not find one on standalone Connect Print Manager installations.
Issue with image placement in 2019.1 when using some customized AFP and IPDS Printer Definitions An issue with image placement in Connect 2019.1 AFP and IPDS output was discovered just prior to the release. The issue is specific to AFP and IPDS 600 DPI Printer Definitions that are not set to "Scale to Fit". As "Scale to Fit" is now switched on by default in all standard Connect 2019.1 AFP and IPDS Printer Definitions, none of those should encounter the issue.
Backend database might require periodic maintenance Databases maintain a variety of statistics in order to optimize performance. When high levels of inserts and/or deletions occur, the statistical data keeping can struggle to keep up. Over a period of prolonged and intensive processing this can result in a degradation in performance, with the whole database slowing down as it struggles to clean itself up.
Windows 10 Search service impacting Connect The Windows 10 Search service runs as a background task, indexing files and folders. It has been noted that this background task is sometimes preventing files being added to the Connect temporary files folder when large amounts of files are being output and copied. If this is an issue for you, we suggest disabling Search Indexing on the C:\Users\\Connect folder. This issue will be fixed in a later release.
All charts l l Legend position: The position of the legend is not converted. It defaults to 'left' in a converted chart. NOTE: Expanded custom chart scripts cannot be converted. Pie charts l Default colors: The default colors (used when no pie chart colors are specified) have changed. Known Font issues The following font(s) are known to have issues in PrintShop Mail Connect 2020.1: l Benton Sans CFF font Minor differences in PCL, AFP and IPDS output introduced in 2018.
Please note, however, that the Objectif Lune Inc. Update Client application might be blocked by the enhanced security settings in Windows Server 2016. To fix this, add http://updates.ca.objectiflune.com to the list of trusted web sites on that machine, or lower the internet access rules. Limit of 100MB of image files within a single job The browser component (Mozilla Gecko) used in the WYSIWYG editor of the Designer was updated for Connect 2018.1. This allows use of new CSS properties, such as flexbox.
Installation paths with multi-byte characters When installing the Traditional Chinese or Japanese versions of Connect, if the user specifies an alternative installation path containing multi-byte/wide-char characters it can break some of the links to the Connect-related shortcuts in the Start Menu and cause an error to appear at the end of the installer. The workaround for the moment is to use the default installation path. The problem will be addressed in a later release.
correctly. For this reason those users should activate Place all certificates in the following store and then select the Trusted Root Certification Authorities as the target certificate store. MySQL Compatibility The minimum supported MySQL version is MySQL 5.6. Available Printer Models Note that only the single Printer Model (Generic PDF) will appear on the Advanced page of the Print Wizard by default. To add additional printer models click on the settings entry box.
VIPP Output Some templates set up with landscape orientation are being produced as portrait in VIPP. It can also sometimes be the case that text and images can be slightly displaced. These are known issues and will be addressed in a later release of Connect. Magic Number changes when installing Docker Installing Docker on a system where Connect has already been installed may impact Connect's licensing mechanism and require reactivation.
Uninstalling This topic provides some important information about uninstalling (removing) PrintShop Mail Connect2020.1. To uninstall PrintShop Mail Connect select the application from within the Add/Remove programs option under the Control Panel. This will start the PrintShop Mail Connect Setup Wizard in uninstall mode. Note The PrintShop Mail Connect Setup Wizard might take some seconds to appear. Important: Stop any active Anti-Virus software before uninstalling Connect.
Uninstallation Wizard The uninstallation is done by running the PrintShop Mail Connect Setup Wizard in uninstall mode. The Wizard consists of the following pages: 1. PrintShop Mail Connect Setup: An information page, listing what will be uninstalled, and also warning about impacts upon running Applications and Services. 2. Data Management: A page that provides options for backing up or deleting Connect data.
Legal Notices and Acknowledgements Warning: PrintShop Mail Connect is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this program, via any means, in part or in whole, may be prosecuted to the full extent of the law. The license agreements for the associated open source third party components can be found in the following installation folder: C:\Program Files\Objectif Lune\OL Connect\Legal Notices This application uses the following third party components:
source can be obtained from here: https://wikis.oracle.com/display/GlassFish/Java+EE+7+Maven+Coordinates l Google Core Protocol Buffers library which is distributed under a BSD 3-clause License l Hamcrest Matchers Copyright © 2000-2006, www.hamcrest.org. All rights reserved. l HyperSQL, Copyright © 2001-2010, The HSQL Development Group. All rights reserved. l l l l l l l l l l IcoMoon. Connect uses unmodified icons from IcoMoon (https://icomoon.
can be found at the following location: http://repo1.maven.org/maven2/org/glassfish/jersey/jersey-bom l l l l l l l l l l l JNA Version 3.5.1 which is distributed under the terms of the GNU Lesser General Public License Version (LGPL) 2.1. The source code for this can be obtained from the following location: https://github.com/twall/jna/releases Logback which is distributed under the terms of the Eclipse Public License (EPL) Version 1.0.
l Spring Framework which is distributed under the terms of the Apache Software License Version 2.0. This product includes sub-components with separate copyright notices and license terms. l StAX Utilities Copyright © 2007, StAX Utilities Project. All rights reserved. l Stax2 API Copyright 2010-2018 FasterXML.com. l l l l l Tern which is distributed under the terms of the Eclipse Public License (EPL) Version 1.0. The source code for tern can be obtained from the following location: https://github.
l Apache Commons DBCP l Apache Commons Digester l Apache Commons Imaging l Apache Commons IO l Apache Commons JCS Core l Apache Commons Lang l Apache Commons Logging l Apache Commons Math l Apache Commons Pool l Apache Commons Text l Apache Commons Validator l Apache Derby l Apache Felix and dependencies l Apache Geronimo l Apache HttpClient Mime l Apache POI l Apache ServiceMix l Apache Xerces2 Java Parser l Apache XML Graphics l Apache XML Beans l Barcode4j l Go
l org.json.simple l Quartz Scheduler l Snakeyaml l SNMP4J l Spring Dynamic Modules l UCanAccess l Woodstox Eclipse Technology: This Software includes unmodified Eclipse redistributables, which are available at www.eclipse.org. The Eclipse redistributables are distributed under the terms of the Eclipse Public License - v 1.0 that can be found at https://www.eclipse.org/legal/epl-v10.html.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY END USER LICENSE AGREEMENT AND LIMITED WARRANTY IMPORTANT – PLEASE READ CAREFULLY Thank you for choosing Objectif Lune’s software. This End User License Agreement and Limited Warranty (hereinafter collectively the "License Agreement") constitute a legal agreement between the End User, either as a physical person or as a legal entity ("you"), and Objectif Lune Inc.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY THIS SECTION STATES THE ENTIRE LIABILITY OF OL REGARDING INFRINGEMENT BY THE SOFTWARE OR ANY OTHER PRODUCT OR SERVICE PROVIDED BY OL. PRE-TESTING OF THE SOFTWARE. - You acknowledge that the Software must be thoroughly tested by you with noncritical data before you rely on it and you hereby assume the entire risk of using the Software. WARNING - HIGH RISK ACTIVITIES.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY If the Software was not provided to you through a leasing or a subscription agreement, you may transfer it to a third party on a permanent basis, after prior written authorization of OL. In case of permanent transfer, you shall not retain any copy of the Software and the transferee shall be bound by the terms of this License Agreement.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY date. Acceptance of the modifications by selecting "I AGREE" and your subsequent use of the Software will be deemed your acceptance of these modifications. This License Agreement shall be binding upon the parties hereto and their respective successors and permitted assignees. If any or part of any provision of this License Agreement is, by final judgment, found void or unenforceable, the remainder shall remain valid and enforceable according to its terms.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY modify, adapt, translate, reverse engineer, decompile, disassemble or otherwise attempt to discover the source code of the Software. Except as stated above, this Agreement does not grant you any intellectual property rights in the Software. FONT LICENSE.
END USER LICENSE AGREEMENT AND LIMITED WARRANTY NOTICE OF RESTRICTED RIGHTS. - "Programs delivered subject to the DOD FAR Supplement are 'commercial computer software' and use, duplication, and disclosure of the programs, including documentation, shall be subject to the licensing restrictions set forth in the applicable Oracle license agreement.