2018.2

Table Of Contents
OL Connect Send
Re-install OL Connect Send on the new Workstation. This should reinstall the OL Connect
Send plugins in the Workflow Tool
Reconfigure the Server URL and port during the OL Connect Send Printer Driver setup
Re-run the OL Connect Send printer driver setup on client system and select the Repair
option to point the clients to the new Server URL.
Configuring the Connect Engines
Any changes made to the Server preferences require the OLConnect_Server service to be
restarted to take effect.
l Stop the OLConnect_Server service from Control Panel > Administrative Tools >
Services > OLConnect_Server > Stop
l Configure the Merge and Weaver Engines scheduling preferences as in the previous
installation
l Open the Server Configuration from :
C:\Program Files\Objectif Lune\OL Connect\Connect Server
Configuration\ServerConfig.exe
l Configure the Merge and Weaver engines preferences under Scheduling (see
Engine configuration)
l Configure any other options for the Clean-up Service
l Configure the minimum (Xms) and maximum (Xmx) memory utilization for the Server,
Merge and Weaver engines as previously or better (see Memory per engine):
l Edit the following Xms and Xmx fields in the following configuration files:
l
C:\Program Files\Objectif Lune\OL Connect\Connect
Server\Server.ini
l
C:\Program Files\Objectif Lune\OL Connect\Connect Merge
Engine\MergeEngine.ini
l
C:\Program Files\Objectif Lune\OL Connect\Connect
Weaver Engine\WeaverEngine.ini
l
Now start the OLConnect_Server service
Page 63