Deuterium Light Source D-2000 / D-2000-DUV / D-2000-S / D-2000-S-DUV Installation and Operation Manual Document Number 000-10000-020-02-1209 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 Fax 727.733.3962 8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST Ocean Optics Mikropack Maybachstraße 11, D-73760, Ostfildern, Germany Phone +49 (0)711 34 16 96-0 Fax +49 (0)711 34 16 96-85 E-mail: Info@OceanOptics.com Info@Mikropack.de Orders@OceanOptics.
Copyright © 2009 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Ocean Optics, Inc.
Important Safety Notices 1. Do not remove or modify any installed safety device on this equipment. Doing so will void your warranty and create an unsafe operating environment. 2. Dangerous voltages are present in this device. There are NO user serviceable parts inside. 3. Only allow qualified personnel to service this unit. 4. Do not use the unit if it is damaged in any way. Contact your dealer for repair or replacement information. 5. Always screw in the fiber optic cables before starting the instrument.
Important Safety Notices B 000-10000-020-02-1209
Table of Contents About This Manual .............................................................................................................iii Document Purpose and Intended Audience.............................................................................. iii What’s New in this Document ................................................................................................... iii Document Summary..............................................................................................
Table of Contents Appendix A: Bulb Replacement .........................................................13 Replacing the Deuterium Bulb ...........................................................................................13 Index ......................................................................................................
About This Manual Document Purpose and Intended Audience This document provides you with an installation section to get your system up and running. What’s New in this Document This version of the Deuterium Light Source D-2000 / D-2000-DUV / D-2000-S / D-2000-S-DUV Installation and Operation Manual updates the logo and the contact information. Document Summary Chapter Description Chapter 1: Setup Contains a list of package contents and unpacking instructions.
About This Manual Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. Please contact an Ocean Optics Application Scientist for specific instructions when returning a product.
Chapter 1 Setup Overview The following sections provide instructions on unpacking and setting up your D-2000 Deuterium Light Source. Before using the D-2000 for the first time check for transport damage. Be sure to adhere to all warnings on the unit and in this manual.
1: Setup Unpacking the D-2000 ► Procedure 1. Unpack your lamp assembly carefully. Although the lamp is rigidly mounted, dropping this instrument can cause permanent damage. 2. Inspect the outside of the instrument and make sure that there is no damage. Do not use the instrument if damage is present. 3. Use this instrument in a clean laboratory environment (see Operating Environment).
Chapter 2 D-2000 Specifications This section provides information on the operating environment, physical controls, and dimensions of the D-2000. It also provides a graph of spectral lines. Operating Environment The following table provides information on optimizing the operating environment of your D-2000. Operating Environment The D-2000 Unit . . . Moisture Is designed for operation in dry rooms only.
2: D-2000 Specifications Front Panel Deuterium On/Off Mechanical Protection –SMA Connector Deuterium Lamp State LED Power LED Component Description Deuterium On/Off Press to turn the Deuterium lamp on or off. The bulb requires a warm-up time of 20 seconds before the Deuterium lamp is illuminated. You must allow the bulb to warm up to receive accurate data from the lamp. LED lights green upon successful illumination, or red to indicate lamp malfunction.
2: D-2000 Specifications Rear Panel 15-pin Connector Cooling Fan Type Sign Main Power Switch Fuse Power Terminal Input Component Description Connect power cable to provide voltage to D-2000: Power Terminal Input Main Power Switch Note: Only connect the power cable to the lamp when the Main Power Switch is in the OFF position. Turn on to supply power to the D-2000. The Power LED illuminates when this switch is in the On position.
2: D-2000 Specifications Specifications Specifications Criteria Wavelength Range 210–400 nm (190–400 nm DUV) Current – Voltage – Stability 0,01 % / h Current – Voltage – Drift 0,01 % / h Warm-Up Time 40 minutes Lamp Voltage Ignition 580V / 20° Lamp Current Operating 85 V / 0.3A Lamp Lifetime 1000 hours Radiation Characteristics Aperture 0.5mm NA26° (13°) Performance Guaranteed Temperature 5°C–35°C Shutter-Input (Only –S / -FHS versions) TTL-Input, up to max.
2: D-2000 Specifications Pinout Information The following table contains pinout information for the D-2000 Light Source: Pin Description 1 na 2 na 3 na 4 na 5 na 6 na 7 na 8 na 9 na 10 Ground 11 na 12 na 13 TTL Signal – Shutter control 14 na 15 na na = not applicable Pinout Diagram 000-10000-020-02-1209 7
2: D-2000 Specifications Spectral Lines 8 000-10000-020-02-1209
Chapter 3 Operating Instructions Operating the Lamp The following sections provide instructions on operating the D-2000 Light Source. Starting the Lamp Press the Deuterium On/Off switch down to preheat the D-2000’s Deuterium lamp. The bulb requires a 20 second preheating period. You must allow this warm up period in order to receive accurate data. After the warm up period, the Deuterium lamp will illuminate.
3: Operating Instructions 10 000-10000-020-02-1209
Chapter 4 Troubleshooting If the power supply or lamp does not seem to functioning properly, check the following: Issue Probable Cause Resolution Power switches on, but no LEDs light. Line power not present Check line voltage Fuse defective Check fuse Allow Deuterium lamp to cool down (20 minutes). Deuterium lamp does not ignite. The two-color LED under the Deuterium On/Off switch lights up red, indicating an error.
4: Troubleshooting 12 000-10000-020-02-1209
Appendix A Bulb Replacement To order replacement bulbs for the D-2000, order the following item number(s): Standard bulb: D-2000-B Deep ultraviolet bulb: D-2000-B-DUV Replacing the Deuterium Bulb ► Procedure 1. Open the six slotted screws (14) and open the casing cover. 2. Open the screws (15) with the tool (18) that is delivered with the spare bulb (16). 3. Disconnect the old bulb and connect the new Deuterium lamp only with the originally supplied connection plugs (17).
A: Bulb Replacement 14 000-10000-020-02-1209
Index B bulb replacement, 13 C S setup, 1 specifications, 3 spectral lines, 8 T components, 3 front panel, 4 rear panel, 5 troubleshooting table, 11 U D unpacking procedure, 2 upgrades, iv document audience, iii purpose, iii summary, iii W O warranty, A what's new, iii operating environment, 3 P package contents, 2 pinouts, 7 product-related documentation, iii 000-10000-020-02-1209 15
Index 16 000-10000-020-02-1209