Owners Manual

2
SPECIFICATIONS
2OACH
MODEL: 2OACH 1211 1811 2412 3612 3632 3634 6012 6032 6034
COOLING CAPACITY 11,800 16,800 24,020
HEATING CAPACITY 11,000 15,600 22,000
VOLTAGE (V/Phase) at 60Hz 208-230/3 460/3 208-230/1 208-230/3 460/3
AMPS 10.4 14.1 14.9 19.6 17.2 8.7 32.0 20.4 14.8
TOTAL WATTS 1180 1670 2700
IN-RUSH CURRENT (AMPS) 60 75 68 113 93 60 178 162 87
PLUG TYPE 5-15P 5-20P 6-20P 6-30P L15-30P L16-20P 6-50P L15-30P L16-20P
EER 8.9
COMPRESSOR HP 1 1 1/2 2
COMPRESSOR RLA 9.5 12.3 10.5 13.6 8.8 5.0 27.6 18.1 9.0
COMPRESSOR LRA 50 63 48 83 77 35 158 137 62
EVAP CFM 400 600 810
EVAP MOTOR HP
CONDENSER CFM 580 930 1010
COND MOTOR HP 1/3
CONDENSATE
R-410A CHARGE (oz.) 18 40 37
(A) HEIGHT (in.) 37-3/4
(B) WIDTH (in.) 20
(C) DEPTH (in.) 25
NET WEIGHT (lb.) 180 400 520
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 2OACHSPECS010119
115/1
1200
1950
60,100
53,500
36,050
32,500
3620
6000
10.0
10.0
3
5
5 Gallon Condensate Tank - STANDARD (Pump Optional)
Pump - STANDARD (20 ft. Lift)
66
80
45-3/4
50-1/4
51-3/4
24
27-1/2
365
30
35
39-1/2
260
485
2200
1
1
1/8
1/3
1390
1/8
NOTES
* Dedicated Circuit and Time Delay fuse or Circuit Breaker are recommended
* Cooling Capacity is total BTUH at 80°DB/67°WB return air, with 95° DB Condenser Air
* Heating Capacity is total BTUH at 70°DB/60°WB Indoor, 47° DB/43° WB Outdoor
* CFM with free discharge
* Cooling EER is determined at high fan speed, with condenser air ducted into another area
* Sound Pressure, dB at 5 feet, commercial operation
* Amps and Watts at 208 Volts (208-230V Models)
COOLING AMBIENT OPERATING RANGE 65° TO 105°
May COOL down to 55° if equipped with hot gas bypass (factory installed)
HEATING AMBIENT OPERATING RANGE 45° TO 85°