Manual
ACCESSORIES
CEILING PANEL DUCT KIT, CK-12, CK-16
A ceiling panel kit is available for discharging the
condenser air above a drop ceiling.. The ceiling
panel duct kits are furnished with a white vinyl
coated flexible duct that allows for convenient
installation. A 2ft X 2ft ceiling duct- panel is
included to replace a 2ft X 2ft drop-ceiling panel
where the connection is desired.
The CK-12 is available for all 2OACH-models
except the 5-ton. The ceiling panel kit consists of
8 feet of flexible duct, a 2' X 2' lay in ceiling panel
and a 12 inch duct flange that attaches to the
condenser air discharge opening on the top of
the unit. The CK-16 (for 5-ton units) consists of a
ceiling duct-panel, and a 16 inch flexible duct.
Note—Drop ceiling spaces should be vented
or large enough to handle the warm
condenser air. Check local codes to assure
compliance.
If longer runs of duct are required, table below
lists maximum duct run with no 90° elbows. For
every 90° elbow, subtract 6 feet from the run.
Ceiling
Kit
Model
Flexible
Duct
Diameter X
Length
Fits
2OACH12
Fits
2OACH18
Fits
2OACH24
Fits
2OACH36
Fits
2OACH60
CK-12
12 inch X
8 feet
No No
CK-16
16 Inch X
8 feet
No
No No
25
(.20)
50
(.25)
50
(.25)
50
(.25)
100
(.50)
Maximum Equivalent
Feet (approx)
(ESP)
2 x 2 CEILING
DUCT-PANEL
VINYL COATED
FABRIC DUCT
DUCT FLANGE
DUCT STRAP
DUCT FLANGE (DF-12, DF-16)
The optional duct flange allows for round flexible ducting to
be attached to the CONVERTIBLEAIRE condenser dis-
charge. DF-12 (12-inch diameter) fits all units except the 5
ton. The DF-16 (16 inch diameter) fits only the 5 ton Model
2OACH60.
NOTE: 2OACH36 and 2OACH60 units come with duct
flanges installed.
DUCT FLANGE
11