Specifications

ConvertibleAire
Deluxe Heat PumpAir-Cooled Portable s
Specifications subject to change without notice
C
US
Note: Condenser inlet air plenum adds
13 inches to dimension C”
D
B
A
C
MODEL: 2OACH
1211
1811 2412 3612 3632 3634 6012 6032 6034
Cooling Capacity
1
1,0018
1, 0680 24,020 36,050 36,050 36,050 60,050 60,050 60,050
Voltage (V/Phase) at 60Hz
115/1
208-230/1 208-230/1 208-230/3 460/3 208-230/1 208-230/3 460/3
Cooling Amps
6
10.4
14.1 14.9 18.1 17.2 8.7 32.0 20.4 14.8
Cooling Watts
6
1180
1067 2007 3062 3062 3062 60 00 6000 6000
In Rush Current (Amps)
77.5
100.5 90 140 122 122 169 140 140
Plug Type
5-15P
5-20P 6-20P 6-30P L15- 0P3 L1 20P6- 6-50P L15-30P L16- 0P2
EER
3
10.0
10.0 8.9 10.0 10.0 10.0 10.0 10.0 10.0
Compressor HP
1
11/22333555
Compressor RLA
9.5
12.3 10.5 13.6 8.8 5.0 27.6 18.1 9.0
Compressor LRA
50
63
48 837735158 137 62
Evap CFM
4
400
600 810 1310 1310 1310 1950 1950 1950
Evap Motor HP
1/8
1/8 1/3 1/3 1/3 1/3 111
Evap Motor Watts
200
210 350 375 375 375 550 550 550
Condenser CFM
580
930 1010 1390 1390 1390 2200 2200 2200
Condenser Motor HP
1/8
1/8 1/3111111
Condenser Motor Watts
280
450 330 750 750 750 750 750 750
Condensate
5 Gallon Condensate Tank - STANDARD (Pump Optional)
Pump )-STANDARD (20 ft. Lift
Sound Level
5
54
60 65 69 78
R- Charge Oz.410A
18
40
37 66 80
(A) Height with Casters (in.)
36 1/2
44 1/2 50-1/4 52 1/4
(B) Width (in.)
20
24 28
(C) Depth (in.)
25
30 35 39
(D) Height Casters (in.)w/o
32 1/2
39* 1/2
45
46
Net Weight (lb.)
180
260 260
365
485 485 515
Shipping Weight (lb.)
200
285 285
405
525 525 555
Shipping Volume (cu. ft.)
19
2840 48
380
420
SPECIFICATIONS
1. Cooling Capacity is total BTUH at 80ºF DB/67ºF WB return air, 95ºF
(Outdoor), at high fan speed. Heating Capacity is total BTUH at
70ºF DB/60ºF WB (Indoor), 47ºF DB/43ºF WB (Outdoor)
2. Time Delay fuses/circuit breakers are recommended
3. EER is determined at high fan speed, with condenser
discharge air ducted out of area
4. CFM with free discharge
5. Sound Pressure, dB at 5 feet, commercial operation
6. Amps & Watts at 208 Volts
May operate down to 55º if equipped with hot gas bypass (Optional)
Ambient operating range 65º to 105º
50 Hz MODELS AVAILABLE - CONSULT FACTORY
Oceanaire, Inc.
6228 Oakton Street Morton Grove, IL 60053
(847) 583-0311, Fax (847) 583-0312
HeatingCapacity
1
1,0010
1, 0560 24,020 3 02,50 302,50 302,50 53,500 53,500 53,500