ATOM 3.0 OPERATING MANUAL ATOM 3.0 DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2011 1 Doc. No.
ATOM 3.0 OPERATING MANUAL CONTENTS WARRANTY, NOTICES, MODEL..........................................................3 FEATURES/FUNCTIONS AND WATCH MODE....................................5 DISPLAY ICONS................................................................................6 ABBREVIATIONS/TERMS................................................................6 OVERVIEW........................................................................................7 SELECTION GROUPS...........................
ATOM 3.0 OPERATING MANUAL CONTENTS (continued) REFERENCE.......................................................................................46 PC INTERFACE...............................................................................47 CARE AND CLEANING...................................................................47 INSPECTIONS AND SERVICE........................................................47 BATTERY REPLACEMENT.............................................................
ATOM 3.0 OPERATING MANUAL Welcome to OCEANIC and THANK YOU for choosing the ATOM 3.0 © 2002 Design, 2011 4 Doc. No.
ATOM 3.0 OPERATING MANUAL FEATURES/FUNCTIONS AND WATCH MODE © 2002 Design, 2011 5 Doc. No.
ATOM 3.
ATOM 3.0 OPERATING MANUAL OVERVIEW The ATOM 3.
ATOM 3.0 OPERATING MANUAL AUDIBLE ALARM While operating in NORM or GAUG Mode, the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that time, the audible can be acknowledged and silenced by pressing the S button (< 2 sec). An LED warning light on the housing is synchronized with the audible and flashes as the Audible sounds. It will turn Off when the alarm is silenced. The audible and light will not be active if the audible is set Off (a group A setting).
ATOM 3.0 OPERATING MANUAL POWER SUPPLY • Watch Battery >> (1) 3 vdc, CR2430, Lithium battery. • Shelf life >> up to 7 years (when shipped from factory in Deep Sleep mode). • Use life >> 1 year or 300 dive hours if (2) 1 hour dives per dive day. • TMT (Transmitter) Battery >> (1) 3 vdc, CR2, .75 Ahr, Lithium battery. • Use life >> 300 dive hours if (2) 1 hour dives per dive day. • Replacement >> user replaceable (annual recommended). Battery icon (applies to ATOM 3.
ATOM 3.0 OPERATING MANUAL WATCH MAIN (DEFAULT) TIME Selection of Main (Default) Time is a Set T menu item. Time of day and date can be set when either Home or Away time is selected as the default. Main Time is the current time at your home location and is normally selected as the Watch Default Time. Away Time, set by Hour Differential, is the current Time at a remote travel location.
ATOM 3.0 OPERATING MANUAL SHOW DUAL TIME This selection allows Dual Time, which is set by an hour differential, to be added, or removed from, to the Watch Main screen. Dual Time Lead-in, information includes (Fig. 10): > Graphics Goto, SHOW, and DUAL. • S (< 2 sec) - to access Show Dual Time. • A (< 2 sec) - to step forward to CDT Lead-in. • M (< 2 sec) - to step back to Watch ALT. Show Dual Time, information includes (Fig. 11): > Graphic YES (or NO) flashing, or 2 dashes ( - - ) if no differential is set.
ATOM 3.0 OPERATING MANUAL CHRONOGRAPH The Chronograph is a stop watch timer for use in Watch mode. While the Chronograph is running, it remains on the screen until another screen is accessed, it will then continue to run in the background while on the surface until stopped and reset. When a dive is started (descent to 5 FT/1.5 M), Chrono operation will be terminated and the time will reset to 0:00_00. Chrono Lead-in, information includes (Fig. 16): > Graphics Goto and CHRO. Fig.
ATOM 3.0 OPERATING MANUAL SET T GROUP (TIME) Sequence >> Lead-in >> Date Format >> Hour Format >> Default Time >> Dual Time >> Time of Day >> Date. Set Points remain as set until changed. Set T Lead-in, information includes (Fig. 23): > Graphics Goto and SET t. • S (< 2 sec) - to access Set Date Format. • A (< 2 sec) - to step forward to Watch Main Time. • M (< 2 sec) - to step back to Daily Alarm Lead-in. Fig. 23 - SET T LEAD-IN Set Date Format, information includes (Fig.
ATOM 3.0 OPERATING MANUAL Set Time of Day, information includes (Fig. 29): This setting directly changes the Time of Day, whichever one is selected as the Default, Home Time or Away. The other will be changed by the Dual Time (Hour Differential) set. > Graphics SEt and HOME (or AWAY). > Time of Day (hr:min), Hour digits flashing, with AM (or PM) icon if 12 Hour Format, no icon if 24 Hour.
ATOM 3.0 OPERATING MANUAL NORM SURFACE MODES © 2002 Design, 2011 15 Doc. No.
ATOM 3.0 OPERATING MANUAL NORM SURF MAIN, information includes (Fig. 32): > (PZ+) icon, if selected as Algorithm, no icon if DSAT. > CF icon, if Conservative Factor is set On. > Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since mode access. > Graphic NOR. > Dive number with # icon, up to 24 for that operating period (0 if no dive made yet). > TMT 1 Pressure with PSI (or BAR) and link (speaker) icons, if active. #1 is the default in Surface Mode.
ATOM 3.0 OPERATING MANUAL TIME TO FLY (NORM/GAUG) Time to Fly is a countdown timer that begins counting down from 23:50 to 0:00 (hr:min) 10 minutes after surfacing from a dive (NORM, GAUG, or FREE). FLY, information includes (Fig. 37): > Time to Fly countdown (hr:min), - : - - if no dive yet, 0:00 if time has elapsed. > Graphic FLY. • A (< 2 sec) - to step forward to DSAT if NORM, or LOG if GAUG. • M (< 2 sec) - to step back to ALT 3 if Nitrox, or ALT 2 if Air or GAUG. Fig.
ATOM 3.0 OPERATING MANUAL • • • • A (< 2 sec) - to step forward through PDPS screens. A (hold) - to scroll forward through PDPS screens (8/sec) from 30 to 190 FT (9 to 57 M) in increments of 10 FT (3 M). M (< 2 sec) - to step back through PDPS screens. S (< 2 sec) at any time - to exit and revert to Plan Lead-in. LOG MODE (NORM/GAUG) Information from the latest 24 NORM and/or GAUG dives is stored for viewing. > After exceeding 24 dives, data for the most recent dive is recorded and the oldest is deleted.
ATOM 3.0 OPERATING MANUAL SET F GROUP (FO2), NORM only Selections >> FO2 Gas 1 > FO2 Gas 2 > FO2 Gas 3 > FO2 50% Default. > FO2 settings revert to AIR 24 hours after a dive. > The FO2 50% Default remains as set until changed.
ATOM 3.0 OPERATING MANUAL SET A GROUP (ALARMS), NORM/GAUG Selections >> Aud > Depth > EDT > Turn > End > TLBG* > DTR* > PO2* *Items apply to NORM only. > Set Points remain as set until changed. Set A Lead-in, information includes (Fig. 49): > Graphics Goto and SET A. • A (< 2 sec) - to step forward to SET U. • M (< 2 sec) - to step back to SET F. • S (< 2 sec) - to access Set Audible Alarm. Fig. 49 - SET A LEAD-IN Set Audible Alarm, information includes (Fig. 50): > Graphics SEt and AUD AL.
ATOM 3.0 OPERATING MANUAL Set End Alarm (TMT 1, 2, 3) information includes (Fig. 56): > Graphics SEt and END AL with all Tank icons (1, 2, 3). > Set Point graphic OFF (or Pressure value) flashing, with PSI (or BAR) icon. • • • • • A (hold) - to scroll upward through Set Points (8/sec) from 300 to 1500 PSI (20 to 105 BAR) in 100 PSI (5 BAR) increments. A (< 2 sec) - to step upward through Set Points. M (< 2 sec) - to step back through Set Points. S (< 2 sec) - to save the setting and access Set PO2 Alarm.
ATOM 3.0 OPERATING MANUAL Set SS (NORM Safety Stop), information includes (Fig. 62): > Graphics SEt and SAFE St with Stop arrow/bar icons. > Set Point graphic ON (or OFF) flashing. A - or - > Graphic SEt with Stop arrow/bar icons. > Set Point graphic ON TMR flashing. • A (< 2 sec) - to step forward through the Set Points (SAFE St OFF, SAFE St ON, TMR ON). • S (< 2 sec) - to save the setting. • S (2 sec), if no change - to revert to Set DS. B >> If SS OFF (Fig. 60A, page 58) or TMR ON (Fig.
ATOM 3.0 OPERATING MANUAL Set TMT 1, information includes (Fig. 67): > Graphics SEt and TMT1 with Tank 1 icon. > Set Point graphic OFF (or ON) flashing. • • • • A (< 2 sec) - to step forward through the selections of OFF, ON, and SN. M (< 2 sec) - to step back through the selections. S (< 2 sec) - to save the selection. S (2 sec), if no change - to step back to Set SR.
ATOM 3.0 OPERATING MANUAL SELECT DIVE OP (OPERATING) MODE Selections >> NOR > GAU > FRE. Lead-in, information includes (Fig. 73): > Graphics Goto, SEL, and DIVE OP. • A (< 2 sec) - to step forward to History. • M (< 2 sec) - to step back to SET U. • S (< 2 sec) - to access Select Dive Op Mode. Fig. 73 - SET M LEAD-IN Select Dive Op Mode, information includes (Fig. 74): > Graphics SEL and DIVE OP. > Mode graphic flashing. • • • • A (< 2 sec) - to step forward through selections of NOR, GAU, and FRE.
ATOM 3.0 OPERATING MANUAL ATOM Batt Status, information includes (Fig. 79): > Graphics bAtt and ATOM. > Graphic Good (if => 2.75 v) or LOW (if < 2.75 v). > Battery icon, if Low (< 2.75 v), flashing (if < 2.50 v). TMT Status, information includes: > Graphics bAtt and Good (or LOW) (Fig. 80). > Tank Pressure with PSI (or BAR), Link, and Tank 1 (or 2, 3) icons, if the TMT is active and reporting. - or > Graphics Not AVAIL with Tank 1 (or 2, 3) icon (Fig.
ATOM 3.0 OPERATING MANUAL DIVE MODE FEATURES © 2002 Design, 2011 26 Doc. No.
ATOM 3.0 OPERATING MANUAL NORM DIVE MODE STRUCTURE Surface Mode at 2 FT (0.6 M) for 1 sec at 5 FT (1.5 M) for 5 sec Dive Mode GAS/TMT Switching 2 sec Safety Stop A < 2 sec Main ALTs Deep Stop Main ALTs M S A < 2 sec < 2 sec ack Alarms DIVE MAIN ALTs < 2 sec L closure A Backlight 2 sec DS Preview TRANSMITTER SIGNAL RECEPTION GUIDE Poor Reception Area BEST Reception Area Poor Reception Area Poor Reception Area Poor Reception Area Poor Reception (when greater than 4 feet/1.
ATOM 3.0 OPERATING MANUAL a BAR GRAPHS The ATOM features 2 specific bar graphs. > The one on the left represents nitrogen loading. It is referred to as the TLBG (Tissue Loading Bar Graph). > The one on the right represents ascent rate. It is referred to as the VARI (Variable Ascent Rate Indicator). TLBG (NORM/FREE) The TLBG represents your relative No Deco (Fig. 83a) or Deco status (Fig. 84a). The lower 4 segments represent No Deco status and the top one indicates a Deco condition. Fig.
ATOM 3.0 OPERATING MANUAL SAFETY STOP (SS), NORM No Deco only If set On: Upon ascent to within 5 FT (1.5 M) deeper than the SS Depth set for 1 second on a No Deco dive in which Depth exceeded 30 FT (9 M) for 1 second, a beep will sound and a SS at the Depth set will appear on the Main display with a countdown beginning at the SS Time set and counting down to 0:00 (min:sec). • If the SS was set for OFF or Timer, the display will not appear.
ATOM 3.0 OPERATING MANUAL NORM DIVE MODES © 2002 Design, 2011 30 Doc. No.
ATOM 3.0 OPERATING MANUAL NO > > > > > > > • • • • • DECO DIVE MAIN, information includes (Fig. 92): Current Depth with FT (or M) icon. DTR (min) with NDC (or O2) icon, up to 199. Elapsed Dive Time with EDT and min icons, up to 199. Tank Pressure with Link and PSI (or BAR) icons. Air Time Remaining with ATR and min icons, up to 199. TLBG, and VARI (while ascending). NX, (PZ+), CF, Gas/TMT, DS icons - if they apply. Fig. 92 - NO DECO MAIN A (< 2 sec) - to access ALTs.
ATOM 3.0 OPERATING MANUAL SAFETY STOP MAIN (On), information includes (Fig. 98): > Current Depth with FT (or M) icon. > Stop Depth with FT (or M) icon, Stop icon (arrows, bar), and Stop Time (counting down) with min and sec icons. > Tank Pressure with Link and PSI (or BAR) icons. > Air Time Remaining with ATR and min icons. > TLBG. > NX, (PZ+), CF, Gas/TMT icons - if they apply. • • • • A (< 2 sec) - to access ALTs**. M (2 sec) - to access Gas/TMT Switching. S (< 2 sec) - to acknowledge/silence alarms.
ATOM 3.0 OPERATING MANUAL Deco Stop Alt 3 (if Nitrox), information includes (Fig. 104): > O2 accumulated* with O2% icon. > > > > *This is the % of the per dive or per day allowed max limit of 300 OTU. Current PO2 value (ATA) with PO2 icon. FO2 Set Point (21 to 100%) for gas in use with FO2 icon. NX icon. Gas (tank) icon for gas in use (1, 2, 3). • 5 sec or A (< 2 sec) - to revert to Main. • L (press) - to activate Backlight. Fig.
ATOM 3.0 OPERATING MANUAL VGM (VIOLATION GAUGE MODE) During NORM dives, operation will enter VGM when Deco requires a Stop Depth greater than 70 FT (21 M). It will also enter VGM if Deco is activated during a dive in FREE mode, described later. alt w/ UP Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing. VGM turns the unit into a digital instrument without any decompression or oxygen related calculations or displays.
ATOM 3.0 OPERATING MANUAL HIGH O2 (NORM only) Warning >> at 80 to 99% (240 OTU). Alarm >> at 100% (300 OTU). When O2 reaches the Warning level (80%); the audible sounds during which the O2 value with O2% icon will flash (in place of DTR) (Fig. 114), then DTR will be restored. The O2 icon will remain on flashing (if OTR is DTR) until O2 is < 80%. If O2 reaches the Alarm level (100%); the audible sounds again, the graphic UP will alternate with the O2 value until on the surface (Fig. 115).
ATOM 3.0 OPERATING MANUAL GAS/TMT SWITCHING © 2002 Design, 2011 36 Doc. No.
ATOM 3.0 OPERATING MANUAL SWITCH ROUTINE OVERVIEW > Can only switch when Dive Main screens are displayed. > Cannot switch on surface, except during first 10 minutes. > Cannot switch during alarms. > All dives begin with Gas/TMT 1 (default on surface). > Defaults to Gas/TMT 1, 10 minutes after surfacing. • M (2 sec), while a Dive Main is displayed - to access. • No button action (10 sec) - to revert to Main. NORM Switch Preview, information includes (Fig.
ATOM 3.0 OPERATING MANUAL DIGITAL GAUGE OP MODE © 2002 Design, 2011 38 Doc. No.
ATOM 3.0 OPERATING MANUAL GAUG SURF MAIN, information includes (Fig. 124): > Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since mode access. > Graphic GAU. > Dive number with # icon, up to 24 for that operating period (0 if no dive made yet). > TMT 1 Pressure with PSI (or BAR) and link (speaker) icons, if active. #1 is the default in Surface Mode. > TMT (tank) 1 icon. > Battery icon, if voltage is low. • • • • M (2 sec) - to access Watch Main.
ATOM 3.0 OPERATING MANUAL GAUG DIVE MAIN, information includes (Fig. 129) > Current Depth with FT (or M) icon. > Run Timer (min:sec), if selected for display, up to 199:59. > Elapsed Dive Time with EDT and min icons, up to 999 if no Run Timer; or up to 99 if the Run Timer is displayed. > Tank Pressure with Link, PSI (or BAR), Tank (TMT) icons. > Air Time Remaining with ATR and min icons. > VARI (while ascending). • • • • • • A (< 2 sec) - to access ALT. M (2 sec) - to access TMT Switching.
ATOM 3.0 OPERATING MANUAL FREE DIVE OP MODE © 2002 Design, 2011 41 Doc. No.
ATOM 3.0 OPERATING MANUAL FREE SURF MAIN, information includes (Fig. 133): > Surface Interval time (min:sec up to 59:59, then hr:min) with SURF icon; if no dive, this is time since mode access. > Graphic FRE. > Dive number with # icon, up to 99 for that operating period (0 if no dive made yet). > (PZ+), CF, Battery icons - if they apply. > TLBG with icon, if any after a NORM or FREE dive. • • • • M (2 sec) - to access Watch Main. A (< 2 sec) - to step forward to FREE SURF ALT 1.
ATOM 3.0 OPERATING MANUAL Set CDT, information includes (Fig. 138): > Graphics SEt and CDT. > Timer setting (min_sec), with Minute digits flashing. • • • • • • • • A (hold) - to scroll upward through Minute Set Points from 0 to 59 (8/sec) in increments of 1 (min). A (< 2 sec) - to step upward through Minute Set Points. M (< 2 sec) - to step back through Set Points. S (< 2 sec) - to save the Minute setting and flash the Seconds digits.
ATOM 3.0 OPERATING MANUAL SHOW NDC TIME This selection allows NDC (No Deco time remaining) to be displayed on the Dive Main in addition to EDT. NDC Lead-in, information includes (Fig. 143): > Graphics Goto, SHOW, and NDC. • S (< 2 sec) - to access Show NDC. • A (< 2 sec) - to step forward to Surface Main. • M (< 2 sec) - to step back to Select Dive OP Mode. Fig. 143 - SHOW NDC LEAD - IN (to access Show) Show NDC, information includes (Fig. 144): > Graphic YES (or NO) flashing.
ATOM 3.0 OPERATING MANUAL FREE DIVE ALARMS FREE mode alarms, which are separate from NORM (or GAUG) alarms, sound either 1 or 3 times as 3 beeps then clear. They cannot be acknowledged or silenced. FREE CDT Alarm When a set Countdown Time reaches 0, the audible will sound during which time the graphic CDT will be displayed with 0 min flashing on the Main (Fig. 147). Fig. 147 - CDT AL FREE EDT Alarm When set On, the EDT alarm activates every 30 seconds during a dive.
ATOM 3.0 OPERATING MANUAL REFERENCE © 2002 Design, 2011 46 Doc. No.
ATOM 3.0 OPERATING MANUAL PC INTERFACE The unit is configured with a Data Port (Fig. 153a) that enables it to be connected to a PC USB port using a special interface cable that is available as an optional accessory. a The USB Driver required for the PC interface system can be downloaded from the Oceanic Worldwide web site. The PC interface system can be used to set/change the Set T group (Watch Time/Date), Set A group (Alarms), Set U group (Utilities), and Set FA group (FREE Alarms).
ATOM 3.0 OPERATING MANUAL BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance of moisture or dust. As an additional precautionary measure to prevent formation of moisture in the Battery Compartment, it is recommended that the Battery be changed in an environment equivalent to the local outdoor temperature and humidity (e.g.
ATOM 3.0 OPERATING MANUAL ALTITUDE SENSING AND ADJUSTMENT Altitude (i.e., ambient pressure) is measured upon activation and every 15 minutes until a dive is made. > Measurements are only taken when the unit is dry. > Two readings are taken, the second reading 5 seconds after the first. The readings must be within 1 foot (30 cm) of each other to record that ambient pressure as the current Altitude. > No adjustments are made during any time that the Wet Contacts are bridged.
ATOM 3.0 OPERATING MANUAL TECHNICAL DATA © 2002 Design, 2011 50 Doc. No.
ATOM 3.
ATOM 3.0 OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Watch • Dive Computer (Air or Nitrox) with up to 3 Gases up to 100% O2 and 3 Transmitters. • Digital Depth Gauge/Timer with up to 3 Transmitters. • Free Dive (breath hold) activity with Depth Gauge/Countdown Timer. DIVE COMPUTER PERFORMANCE • Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm. • No Deco limits closely follow PADI RDP. • Decompression in agreement with Buhlmann ZHL-16c and French MN90. • No Deco Deep Stops >> Morroni, Bennett.
ATOM 3.0 OPERATING MANUAL SPECIFICATIONS (CONTINUED) NUMERIC DISPLAYS: Range: Resolution: • Main Time of Day • Dual Time of Day • Dual Time Differential • Watch Countdown Timer • Watch Chrono Lap # • Watch Chrono Lap Time 00:00_00 to 23:59_59 hr:min_sec 00:00 to 23:59 hr:min - 23 hr to 0 to + 23 hr 23:59 to 0:00 hr:min 1 to 9 0:00 to 1:59:59_99 (hr:min:sec_.01 sec) 1 second 1 minute 1 hour 1 minute 1 (lap) .
ATOM 3.0 OPERATING MANUAL INSPECTION / SERVICE RECORD ATOM 3.0 Serial Number: ___________________________________________________________________________________________________ ATOM 3.
ATOM 3.0 OPERATING MANUAL NOTES © 2002 Design, 2011 55 Doc. No.
ATOM 3.0 OPERATING MANUAL ATOM 3.0 DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2011 56 Doc. No.