Operation Manual
DataPlus
85
SPECIFICATIONS
NO DECOMPRESSION MODEL
Basis:
• Modified Haldanean Algorithm
• 12 tissue compartments
Data Base:
• Diving Science and Technology (DSAT) - Rogers/Powell
Performance:
• Tissue compartment half times (in mins.) Spencer’s “M” values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
• Reciprocal subsurface elimination
• 60 minute surface credit control for compartments faster than 60
minutes
• Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities:
• Decompression stop ceilings at 10, 20, 30, 40, 50, & 60 feet (3, 6, 9, 12,
15, & 18 meters)
Altitude Algorithm:
• Based on National Oceanic & Atmospheric Administration (NOAA)
tables
Oxygen Partial Pressure (PO2) Limits:
• Based on National Oceanic & Atmospheric Administration (NOAA)
tables
OPERATIONAL MODES & DISPLAY RANGE/RESOLUTION
Modes:
• Activation/Diagnostic
• Surface
• FO2 Set
• PO2 Max Depth
• Pre Dive Planning Sequence
• No Decompression Dive
• Decompression Dive
• Alternate Decompression Dive
• Violation (conditional, delayed, & immediate)
• Temperature (& backlight)
• Gauge
• High PO2 Dive
• Dive Log (nitrogen & oxygen)
• Time to Fly
Numeric Displays:
Range Resolution
• Dive # 0 - 9 1
• Depth 0 - 330 ft. (99.5 m) 1 ft. (.5 m)
• Maximum Depth 330 ft. (99.5 m) 1 ft. (.5 m)
• FO2 Set Point 21 - 50 % 1 %
• PO2 Value 1.40 - 9.99 BAR .01 BAR
• No Decompression Time 0 - 9 hrs. 59 mins. 1 minute
• Decompression Time 0 - 9 hrs. 59 mins. 1 minute
• Elapsed Dive Time 0 - 1 hrs. 59 mins. 1 minute
• Surface Time 0 - 11 hrs. 59 mins. 1 minute
• Dive Log Surface Interval 0 - 11 hrs. 59 mins. 1 minute
• Time to Fly 23 hrs. 59 mins. - 0* 1 minute
(* starting 10 sec. after the dive)