Operation Manual

53
VT 4.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5213-r02 (9/6/11)
TRANSMITTER BATTERY REMOVAL
Locate the Battery Cover on the end of the housing:
Apply a coin to the recessed slot of the Cover and turn it counter clockwise out of the housing (Fig. 141).
Remove the Battery and discard it according to local regulations governing disposal of Lithium batteries.
TRANSMITTER BATTERY INSTALLATION
Lightly lubricate the new Battery Cover O-ring with silicone grease and install it onto the Battery Cover. DO NOT roll the
O-ring over the Threads, instead stretch it slightly to work it down over the slotted end of the Cover into the groove at the base
of the threads (Fig. 142).
The O-ring must be a genuine Oceanic part that can be purchased from an Authorized Oceanic Dealer.
Use of any other O-ring will void the warranty.
• Place a new 3 volt CR2 Lithium Battery (Duracell model DL-CR2 or equivalent) positive (+) side down into the Battery
compartment with the negative end facing up/out (Fig. 143).
• Ensure that the Battery is properly oriented and the Cover O-ring is evenly seated around the Cover.
• Carefully place the Cover (with Spring) into the housing and turn clockwise slowly by hand to ensure proper threading.
• Apply a coin and tighten until secure. The outer surface of the Battery Cover should be flush with the outer surface of the
housing (Fig. 144).
INSTALLING A TRANSMITTER ON A REGULATOR
• Remove the existing pressure gauge and high pressure hose, or the high pressure port plug from the port marked HP using
the proper size hex key.
• Lightly lubricate the o-ring and threads of the Transmitter fitting with a halocarbon based lubricant such as Christo-Lube
MCG111.
• Thread the Transmitter clockwise by hand into the regulator's HP port (Fig. 145) and tighten until secure with an appropriate
sized open end wrench.
• Attach the regulator First Stage to a full scuba tank and pressurize by slowly opening the tank valve, listening for any
indication of air leaking around the fitting.
• If air leakage is present, DO NOT use, take the complete regulator assembly to an Authorized Oceanic Dealer for inspection
and service.
TRANSMITTER COMPATIBILITY WITH NITROX
When packaged and shipped from the factory, Oceanic Transmitters are rated for use with compressed Air and/or nitrogen-
oxygen (Nitrox) breathing gas mixtures containing up to 99% O2 by volume and with 100% O2.
Fig. 143 - ORIENTATION
Battery
(+) ( - )
Fig. 141 - COVER
REMOVAL
Fig. 142 - INSTALLING
COVER O-RING
Fig. 144 - TRANSMITTER
COVER INSTALLED
Fig. 145 - TRANSMITTER ON
FIRST STAGE