VT 4.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5213-r02 (9/6/11)

Dive Computer (Air or Nitrox) with up to 4 Gases up to 100% O2 and 4 Transmitters.
Digital Depth Gauge/Timer with up to 4 Transmitters.
Free Dive (breath hold) activity with Depth Gauge/Countdown Timer.
Compass.

Buhlmann ZHL-16c based Pelagic Z+, or DSAT based, algorithm.
No Deco limits closely follow PADI RDP.
Decompression in agreement with Buhlmann ZHL-16c and French MN90.
No Deco Deep Stops >> Morroni, Bennett.
Deco Deep Stops (not recommended) >> Blatteau, Gerth, Gutvik.
Altitude >> Buhlmann, IANTD, RDP (Cross).
Altitude corrections and O2 limits based on NOAA tables.

Battery and Pressure check
> every 2 seconds when awake
Startup
> Pressure => 120 PSI (8 BAR)
> Battery => 2.75 volts
Shutdown
> Pressure < 50 PSI (3.5 BAR)

When packaged and shipped from the factory, Oceanic Transmitters are rated for use with compressed Air and Nitrox mixtures containing up to 99% O2 by volume and with 100% O2.

 Accuracy:
Depth ±1% of full scale
Timers 1 second per day

• Must rst be activated by button press, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Wet Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters).

• 2 hours after activation, if no dive conducted.
• 24 hours after conducting a dive, if no further dives conducted.

NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet).
Resets to Dive #1, upon diving (after 24 hours with no dives).

Stores 24 most recent NORM/GAUG dives in memory for viewing.
After 24 dives, adds 25th dive in memory and deletes the older dive.

Operational from sea level to 14,000 feet (4,270 meters) elevation.
Measures ambient pressure upon activation and every 15 minutes while in Surface modes.
Does not measure ambient pressure when Wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.

• Battery (1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent)
• Transmitter Battery (1) 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
• Shelf life Up to 5 years
• Replacement User replaceable (annual recommended)
• Use Life 1 year or 300 dive hours if (2) 1 hour dives per dive day
• Use Life (Transmitter) 300 dive hours if (2) 1 hour dives per dive day

Warning >> icon on solid when <= 2.75 volts, Battery change recommended.
Alarm >> icon on ashing when <= 2.50 volts, change the Battery, will not function.

Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
In the water >> between 28 °F and 95 °F (-2 and 35 °C).

 segments
• No Deco Normal zone 1 to 3
• No Deco Caution zone 4
• Decompression zone 5 (all)
 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (ashing) 5 (all) > 30 > 9 5 (all) > 60 > 18