Operation Manual

16
Situations that will sound the Alarm, if it is turned ON (a user setting), include -
• Entry into Decompression Mode.
• Air Time Remaining Bar Graph Alarm (a user setting).
• Air Time Remaining = 5 minutes, then 0 minutes.
• Turn Pressure Alarm (a user setting).
• End Pressure Alarm (a user setting).
• PO2 => than the Max PO2 Alarm (a user setting), or => 1.60 ATA.
• Descent deeper than the Max Depth Alarm (a user setting).
• Tissue Loading Bar Graph Alarm (a user setting).
• Dive Time Remaining Alarm (a use setting).
• Elapsed Dive Time Alarm (a use setting).
• O2 Accumulation => allowable per dive limit, or limit for a 24 hour period.
• Ascending above a required Decompression ceiling stop depth for less than 5 minutes
(referred to as a Conditional Violation).
• Ascent Rate exceeds 60 feet/minute (18 meters per minute) if greater than 60 feet (18
meters), or 30 feet/minute (9 meters/minute) at 60 feet (18 meters) and shallower.
• Loss of Transmitter Link signal for > 1 minute during Dive Modes.
A single short beep (which cannot be disabled) is emitted for the following -
• After the Diagnostic countdown, if everything is okay.
• If the unit automatically returns to Surface Mode from Simulator Mode.
• Upon completion of a Hot Swap battery change with calculations saved.
• Change from Delayed to Full Violation 5 minutes after the dive.