Operation Manual

42
Setting Digital Gauge Mode (continued) -
• Press and release the Side (Select) button to toggle between
ON and OFF.
• Press the Front (Advance) button to accept the setting and
advance to Set Water Activation, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
TO SET - WATER ACTIVATION (while in Surface Mode)
Factory set for ON, the Water Activation feature can also be set
for OFF (disabled) to prevent inadvertent activation during travel
or storage. When set ON, the VT Pro will automatically Activate
when immersed in water.
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Front (Advance) button, the Units screen
appears with the set point flashing.
• Press the Front (Advance) button 18 more times
(17 more times after a dive in Digital Gauge Mode).
• The graphics ACT and H20 appear with ON (or OFF)
flashing (Fig. 47).
• Press and release the Side (Select) button to toggle between
ON and OFF.
• Press the Front (Advance) button to accept the setting and
revert to Surface Mode.
Fig. 47 - Set Water Activation
ATR
O
2
WARNING: If
this feature is
set for OFF, the
VT Pro must be
manually
activated prior
to commencing
a dive.