SDS
_____________________________________________________________________________________________
Carcinogenicity
The table below indicates whether each agency has listed any ingredient as a carcinogen.
Chemical name ACGIH IARC NTP OSHA
Supplier Trade Secret A1 Group 1 Known X
Supplier Trade Secret Group 3
ACGIH (American Conference of Governmental Industrial Hygienists)
A1 - Known Human Carcinogen
IARC (International Agency for Research on Cancer)
Group 1 - Carcinogenic to Humans
Group 3 - Not Classifiable as to Carcinogenicity in Humans
NTP (National Toxicology Program)
Known - Known Carcinogen
OSHA (Occupational Safety and Health Administration of the US Department of Labor)
X - Present
Reproductive toxicity
Contains a known or suspected reproductive toxin.
STOT - single exposure
No information available.
STOT - repeated exposure
Causes damage to organs through prolonged or repeated exposure. Based on
classification criteria from the 2012 OSHA Hazard Communication Standard (29 CFR
1910.1200), this product has been determined to cause systemic target organ toxicity from
chronic or repeated exposure. (STOT RE).
Chronic Toxicity
Chronic exposure to corrosive fumes/gases may cause erosion of the teeth followed by jaw
necrosis. Bronchial irritation with chronic cough and frequent attacks of pneumonia are
common. Gastrointestinal disturbances may also be seen. Prolonged exposure may cause
chronic effects. Repeated contact may cause allergic reactions in very susceptible persons.
Possible risk of irreversible effects. Contains a known or suspected carcinogen. Avoid
repeated exposure.
Target Organ Effects
Respiratory system. Eyes. Skin. Gastrointestinal tract (GI). May affect the genetic material
in germ cells (sperm and eggs). Reproductive System.
Aspiration Hazard
No information available.
Numerical measures of toxicity Product Information
The following values are calculated based on chapter 3.1 of the GHS document
ATEmix (oral)
1,078.00 mg/kg
ATEmix (inhalation-gas)
9,065.00 ppm (4 hr)
ATEmix (inhalation-dust/mist)
3.00 mg/l
ATEmix (inhalation-vapor)
22.00 ATEmix
_____________________________________________________________________________________________
1303432 - Ni-MH Battery AA 1500mAh 1.2V
Revision Date 16-Dec-2015
Page 9 / 12